Trouble
The suction does not start
even though the electronic
EN
device is connected to the
extraction unit.
The suction suddenly
stops during automatic
operation, even though the
device connected at the
appliance socket is still in
use. The signal for auto-
matic operation (20, Fig. 2)
is still on.
In the automatic operation
mode, the suction starts af-
ter an unusually long delay
time.
The suction does not start
after long transportation or
after change of turbine.
When the unit is switched
on, not all of the displays
light up.
The fuse is released when
a connected electronic
device is switched on.
The suction process in the
continuous operation or
automatic operation stops
abruptly and the rele-
vant displays are still on
(20 / 22, Fig. 2).
8

Technical Data

Nominal voltage:
Permissible mains voltage:
Mains frequency:
Suction turbine power *):
max� connecting power *):
Total connected power *):
LpA **) (at max. volume flow):
Filterquality:
Weight (empty), approx�:
Dimensions (width x height x depth):
*) at nominal voltage
**) Sound pressure levels according to EN ISO 11202
Possible Cause
• The automatic switch-on function
has been set too high�
• Malfunction due to another device
using the same power circuit�
• Malfunction due to another device
using the same power circuit�
• Malfunction due to another device
using the same power circuit�
• The connection plug behind the
service flap (13, Fig. 1) is not com-
pletely inserted�
• The display which does not light up
is defect�
• The total capacity for the connected
devices is too high�
• The suction turbine is overheated�
• The suction turbine is defect�
2934 0000
220 - 240 V
50 / 60 Hz
Corrective Action
• Setting the automatic switch-on (calibration) (see
chapter 5�5)�
• Connect the extraction unit and the device causing
interference to different power circuits (phases)�
• Connect the extraction unit and the device causing
interference to different power circuits (phases)�
• Connect the extraction unit and the device causing
interference to different power circuits (phases)�
• Open the service flap (13, Fig. 1) and push the con-
nection plug fully up to the top�
• Contact Renfert / Service�
• Observe the max� connected capacity (see chapter 8)�
• Switch the unit off and allow to cool down for at least
60 min�
• Check whether the suction tube is blocked� Eliminate
blockage�
• Switch the unit off and then on again, so that the filter
cleaning process can be carried out�
Change the fine filter (see chapter 6.3) (if the filter
cleaning function does not improve the suction perfor-
mance)�
• Change the suction turbine�
2934 1000
230 V
120 V
120 V
50 / 60 Hz
490 W
480 W
1350 W
480 W
1840 W
960 W
55 db(A)
Class M according to EN60335-2-69
13�2 kg
[29�1 lbs]
245 x 440 x 500 mm
[9�6 x 17�3 x 19�7 inch]
- 14 -
2934 1500
100 V
100 V
50 / 60 Hz
480 W
320 W
800 W