RFSA-166M
Wireless switch unit
EN
Unidad inalámbrica de conmutación
ES

Technical parameters /

Especifi caciones técnicas
Supply voltage:
Apparent input:
Dissipated power:
Supply voltage tolerance:
Output
Number of contacts:
Rated current:
Switching power:
Peak current:
Switching voltage:
Min. DC switching power:
Mechanical service life:
Electrical service life (AC1):
Control
RF, by command from transmitter:
Manual control:
Range in free space:
Output for RF antenna:
Other data
Operating temperature:
Operating position:
Mounting:
Protection:
Overvoltage category:
Contamination degree:
Connecting conductor cross-section
(mm
Dimensions:
Weight:
Related standards:
* Max Tightening Torque for antenna connector is 0.56 Nm.
Attention:
When you instal iNELS RF Control system, you have to keep minimal distance 1 cm between each units.
Between the individual commands must be an interval of at least 1s (Valid for control PRG, AUX).
Warning
Instruction manual is designated for mounting and also for user of the device. It is always a part of its packing.
Installation and connection can be carried out only by a person with adequate professional qualifi cation upon
understanding this instruction manual and functions of the device, and while observing all valid regulations.
Trouble-free function of the device also depends on transportation, storing and handling. In case you notice any
sign of damage, deformation, malfunction or missing part, do not install this device and return it to its seller. It
is necessary to treat this product and its parts as electronic waste after its lifetime is terminated. Before starting
installation, make sure that all wires, connected parts or terminals are de-energized. While mounting and servicing
observe safety regulations, norms, directives and professional, and export regulations for working with electrical
devices. Do not touch parts of the device that are energized – life threat. Due to transmissivity of RF signal, observe
correct location of RF components in a building where the installation is taking place. RF Control is designated only
for mounting in interiors. Devices are not designated for installation into exteriors and humid spaces. The must not
be installed into metal switchboards and into plastic switchboards with metal door – transmissivity of RF signal is
then impossible. RF Control is not recommended for pulleys etc. – radiofrequency signal can be shielded by an
obstruction, interfered, battery of the transceiver can get fl at etc. and thus disable remote control.
ELKO EP ESPAÑA, S.L. | C/ Josep Martinez 15a, bj | 07007 Palma de Mallorca | e-mail: info@elkoep.es | Tel.: +34 971 751 425 | Fax: +34 971 428 076
Made in Czech Republic
Tensión de alimentación:
Consumo aparente:
Consumo de perdida:
Tolerancia de alimentación:
Salida
Número de contactos:
Corriente nominal:
Potencia de conmutación:
Pico de corriente:
Tensión de conmutación:
Conmutación de potencia min.DC:
Vida mecánica:
Vida eléctrica (AC1):
Control
Orden RF desde controlador:
Control manual:
Rango al aire libre:
Salida para la antena RF:
Más información
Temperatura de funcionamiento:
Posición de funcionamiento:
Montaje:
Protección:
Categoría de sobretensión:
Grado de contaminación:
Sección cables de conexión (mm
2
):
Dimensiones:
Peso:
Normas conexas:
ELKO EP, s.r.o. | Palackého 493 | 769 01 Holešov, Všetuly | Czech Republic | e-mail: elko@elkoep.com | Support: +420 778 427 366
www.elkoep.com / www.elkoep.es
110-230 V AC / 50-60 Hz
min. 2 VA / max. 5 VA
min. 0.5 W / max. 2.5 W
+10% / -25 %
3x switching / conmutable (AgSnO
3x switching / NA (AgSnO
8 A / AC1
2000 VA / AC1
10 A / <3 s
250 V AC1
500 mW
1x10
7
1x10
5
  866 MHz, 868 MHz, 916 MHz
button / botón MAN
up to / hasta 200 m
SMA connector / SMA conector *
 
-15 °C ... + 50 °C
any / cualquiera
DIN rail / carril DIN EN 60715
IP20 from the front panel / desde panel frontal
III.
2
2
):
max. 1x2.5, max. 2x1.5 / with a hollow /
con manguera max.1x2.5
90 x 52 x 65 mm
264 g
EN 60669, EN 300 220, EN 301 489 Directives / directiva RTTE,
NVč.426/2000Sb (Directive / directiva 1999/ES)
* Máx. fuerza de apriete para el conector de la antena es de 0.56 Nm.
Advertencia:
En la instalación de iNELS RF Control debe haber una distancia mínima entre las diferentes
unidades de un centímetro.
Entre las diferentes ordenes debe pasar al menos 1s (válido para control de PRG, AUX).
Advertencia
El manual de uso está dirigido para la instalación y el usuario del dispositivo. Manual siempre está incluido en
embalaje. La instalación y conexión puede realizar sólo personal con adecuadas cualifi caciones profesionales, de
conformidad con todas las regulaciones aplicadas, y que está perfectamente familiarizado con estas instrucciones
y funciones del dispositivo. Función del dispositivo también depende del transporte, almacenamiento y la
manipulación. Si se observa cualquier signo de daño, deformación, mal funcionamiento o pieza que falta, no instale
este producto y devolvelo al vendedor. Con el producto y sus componentes debe ser tratado después de su vida
útil como con residuos electrónicos. Antes de iniciar la instalación, asegúrese de que todos los cables, partes o
terminales conectados están sin la conexión a la red. En el montaje y el mantenimiento se deben observar las
normas de seguridad, normas, directivas y reglamentos para trabajar con equipos eléctricos. No toque las partes
del dispositivo que están conectadas en la red - puede producir peligro de vida. Debido a la transmisibilidad de la
señal RF, observe la correcta ubicación de los componentes RF en un edifi cio donde la instalación se lleva a cabo. RF
Control está diseñado para montaje en interiores, las unidades no están diseñados para la instalación en exteriores
y espacios húmedos, no se pueden instalar en cuadros eléctricos de metal y en cuadros eléctricos plásticos con
puerta de metal - lo que empeora transmisividad de la señal RF. RF Control no se recomienda para el control de
dispositivos que ofrecen funciones vitales o para controlar dispositivos tales como bombas, el. calentadores sin
termostato, ascensores, montacargas, etc. - Señal de radiofrecuencia puede estar bloqueado por una obstrucción,
interferida, la batería del controlador puede estar ya sin energía, etc. y por lo tanto el control remoto puede ser
incapacitado.