H-3535
KIHLBERG JK35-590
WIDE CROWN
PNEUMATIC TACKER
LOADING THE MAGAZINE
1.
Pull the pusher all the way back until it snaps in
around the parking button. Feed in a staple strip
from above into the magazine and push it forward
by hand. (See Figure 1)
2. Release the pusher by pressing the parking button.
(See Figure 2)
PAGE 1 OF 12
1-800-295-5510
uline.com
OPERATION
USING THE STAPLER
1. Adjust the air pressure to the lowest one that
Figure 1
Pusher
2. Place the stapler firmly on the work surface. Never
Parking
Button
3. This stapler has only single shot firing with safety yoke.
Figure 2
4. As this stapler is equipped with a safety yoke, it can
Pour le français, consulter les pages 9-12.
WARNING! Be sure that the stapler nozzle is
not pointed at yourself or anyone else when
connecting it to the compressed air line.
will drive staples to the desired depth. Start at
approximately 5.5 bar and raise this by 0.5 bar
increments until the correct operating pressure for
the job is found.
CAUTION! Never exceed 7 bar air pressure. A
low air pressure will reduce maintenance costs!
drive staples into extremely hard or brittle material.
Do not drive staples at too steep an angle or too
close to the edge of the work; the staple might fly
free and cause injury.
a. First place the stapler against the work piece.
b. Then pull the trigger. (See Figure 3)
A
also be bump fired where there is no great need for
stapling precision.
Para Español, vea páginas 5-8.
Figure 3
B
0421 IH-3535