Installation; Hoses And Connections; Methods To Prevent Freezing; Connecting A Water Separator - Chicago Pneumatic CP 0111 CHLA Instrucciones De Seguridad Y De Funcionamiento

Tabla de contenido

Publicidad

Idiomas disponibles
  • ES

Idiomas disponibles

  • ESPAÑOL, página 46
CP 0111 CHLA, CP 0111 CHIT
Data plate
A.
Machine type
Maximum permitted compressed air pressure
B.
Serial number
C.
The warning symbol together with the book
D.
symbol means that the user must read the
safety and operating instructions before the
machine is used for the first time.

Installation

Hoses and connections

Compressed air source
A.
B.
Water separator (optional)
C.
Oiler (optional)
Max. 10 feet compressed air hose between the
D.
oiler and the machine.
Check that you are using the correct
recommended operating pressure, 87 psig (6 bar
(e)).
The maximum permissible air pressure, 90 psig
(6.2 bar (e)), must not be exceeded.
Blow any impurities out of the compressed air
hose before connecting it to the machine.
9800 0809 90
Safety and operating instructions
Select the correct dimension and length for the
compressed air hose. For hose lengths up to 100
feet (30 m), a hose with a minimum internal
diameter of
3
in. (19 mm) should be used. If the
4
hose length is between 100 and 300 feet (30-90
m), a hose with a minimum internal diameter of
1 in. (25 mm) should be used.

Methods to prevent freezing

Ice formation in the muffler can occur when the
ambient air temperature is 32-50 °F (0-10 °C) and
the relative humidity is high.
The machine is designed to avoid the formation of
ice in the muffler. Despite this, under extreme
conditions ice can form in the muffler.
The following actions can be taken to further
counteract the risk of ice formation:
Use an air tool oil containing antifreeze agents.
Use a water separator.
Connecting a water
separator
The length of the air hose between the compressor
and the water separator must be such that the water
vapor is cooled and condenses in the hose before
reaching the water separator.
If the ambient temperature is below 32 °F (0 °C) the
hose must be short enough to prevent the water
from freezing before reaching the water separator.

Lubrication

Lubrication
The lubricant is important for the machine s function
and has a great impact on the service life. In order
to supply the correct volume of oil, an oiler should
be connected to the air hose. The use of Chicago
Pneumatic air line oiler is recommended. To
guarantee good lubrication, the length of the air
hose between the oiler and the pneumatic tool
should not exceed 10 feet (3 m).
Too much lubrication can cause starting problems,
low power or uneven performance.
Recommended Lubricant: Air tool oil with a viscosity
of 100-150 SUS at 100°F (ISO VG 22–32).
It is recomended that the oil contains a rust-inhibitor.
11

Publicidad

Tabla de contenido
loading

Este manual también es adecuado para:

Cp 0111 chit

Tabla de contenido