Safety and operating instructions
Use only authorised parts. Any damage or
malfunction caused by the use of unauthorised
parts is not covered by warranty or product
liability.
When cleaning mechanical parts with solvent,
comply with appropriate health and safety
regulations and ensure there is satisfactory
ventilation.
For major service to the machine, contact your
nearest authorised workshop.

Every day

Before undertaking any maintenance or changing
the insertion tool on pneumatic machines, always
switch off the air supply and bleed the machine by
depressing the start and stop device then disconnect
the air hose from the machine.
Clean and inspect the machine every day.
Check the tool retainer for wear and function.
Conduct a general inspection for leaks and
damage.
Check that the air inlet nipple is tightened and
that the claw coupling is free from damage.
For the machine to maintain the specified
vibration values, always check the following:
Too big a clearance between the insertion tool s
shank and the chisel bushing will generate
increased vibrations. To avoid getting exposed to
excessive vibrations, check the chisel bushing for
wear every day.
Change damaged parts immediately.
Replace damaged and worn components in good
time.
Make sure that all the attached and related
equipment, such as hoses, water separators and
oilers are properly maintained.

Periodic maintenance

After each operating period of approximately 150
impact hours or twice a year the machine must be
dismantled and all parts be cleaned and checked.
This work must be performed by authorised staff,
trained for this task.
14
CP 0111 CHLA, CP 0111 CHIT

Assembly instructions

CP 0111 general
Torque: 115–125 lbf.ft (156–169 Nm)
A.
Torque: 80–85 lbf.ft (109–115 Nm)
B.
Torque: 65–70 lbf.ft (88–95 Nm)
C.
CP 0111 CHIT
Torque: 85–95 lbf.ft (115–128 Nm), use
A.
Loctite® 243™
B.
Torque: 85–95 lbf.ft (115–128 Nm)
Housing peened to retain the pin.
C.
CP 0111 CHLA
A.
Housing peened to retain the pin.
B.
Torque: 85–95 lbf.ft (115–128 Nm), use
Loctite® 243™
Torque: 85–95 lbf.ft (115–128 Nm)
C.

Troubleshooting

If the pneumatic breaker does not start, has low
power or uneven performance, check the following
points.