Pentair Claris ULTRA Guia Al Uso Y A La Instalación página 3

Tabla de contenido

Publicidad

Idiomas disponibles
  • ES

Idiomas disponibles

  • ESPAÑOL, página 7
PENTAIR CLARIS ULTRA filter cartridges
All information in this Pentair Claris ULTRA guide relates to the use of Pentair Claris ULTRA filter cartridges in
combination with Pentair Claris filter heads.
The installation & operation guide attached to the Pentair Claris filter heads is also suitable for use with Pentair Claris
ULTRA filter cartridges, unless specific information is given for Pentair Claris ULTRA in this guide.
1. Application
The Pentair Claris ULTRA filter cartridges are typically used to feed the following appliances:
Coffee and espresso machines
Drinks vending machines
Ice machines
The Pentair Claris ULTRA filter systems fits into all Pentair Claris filter heads.
2. Function
Pentair Claris ULTRA filter cartridges use a new water-conditioning method to optimize the quality of hot drinks and ice
cubes and to protect machine parts from mineral deposits and for water-related aggression.
The incorporated 5 μm membrane carbon block reduces undesirable cloudiness, organic impurities, taste and odour
and chlorine residue from the filtrate.
3. Flushing during installation and replacement of ULTRA fi lter cartridges
Replaces 5.1.1,(5) and 5.1.2 (4) in the Pentair Claris installation & operation guide.
Insert the Pentair Claris ULTRA filter cartridge into the filter head by rotation and screw clockwise until it stops (see
page 3, item 8). This vents the system and flushes the filter cartridge (type ULTRA 170, 250 and 500 > 10 litres / 3 US
gal; 1000 and 1500 > 20 litres / 6 US-gal; 2000 > 30 litres / 8 US-gal).
4. Settings / Capacities
Replaces the table in chapter 10 of the Pentair Claris guide.
The recommended settings and capacities for Pentair Claris ULTRA are mentioned in the tables on page 12.
If the actual hardness degree isn't listed in the tables the recommended settings and capacities of the next listed higher
hardness degree is valid.
Please note: the hardness degrees listed in the capacity tables relate to carbonate hardness (alkalinity).
5. Technical data
Dimensions
Height, fi lter system
Height, fi lter cartridge
Diameter of fi lter cartridges
Min. distance from ground
Weight, fi lter cartridge
Operating data
Max. working pressure
Water temperature / ambient temperature
6. Order information
Description
Filter cartridges
Single fi lter head 3/8" thread, in left/out right
Single fi lter head 3/8" - QCF, in left/out right
Single fi lter head 1/4" - QCF, in left/out right
Disclaimer
Information contained in this document is believed to be accurate at the time of publication, but does not constitute a
contractual offer. The right is reserved to alter specifications without prior notice. Illustrations and tabulated data are for
guidance only. Pentair does not assume liability for any damages, including subsequent damages, that may result from
incorrect installation or usage of the products.
Pentair does not assume liability for damage caused by using parts from other manufacturers.
170
250
[mm]
295
365
[mm]
245
315
[mm]
95
95
[mm]
40
40
[kg]
0.9
1.3
170
250
4339-85
4339-80
3
500
1000
475
410
425
360
95
136
40
40
1.8
3.2
2 - 8 bar (29 - 116 psi)
4° - 30° C (39° F - 86° F)
500
1000
4339-81
4339-82
4339-83
4339-21
4339-23
4339-25
1500
2000
525
525
475
475
136
175
40
40
4.3
6.5
1500
2000
4339-84

Publicidad

Tabla de contenido
loading

Tabla de contenido