Water-Resistant Wall Material
Stud Wall
Cross-Section of the Front Wall
3. Install the Base
WARNING: Risk of property damage. Do not support the shower base by the rim. The weight of
the shower base should be supported by the bottom of the shower base.
WARNING: Risk of property damage. The drain must have a watertight seal. If a watertight seal
on the drain is not obtained, water damage to the subfloor will occur.
Install the drain to the shower base according to the drain manufacturer's instructions. Follow all
local building codes, standards, and regulations.
Move the base into position.
Make sure the shower base is level and the bottom of the shower base is resting on the subfloor.
Shim as necessary.
Clean the surface of the shower base to reduce the risk of surface damage, then place a clean drop
cloth or other similar material into the bottom of the shower base.
Fit the drain into the P-trap. Do not connect the P-trap at this time.
Verify the base is level.
Complete the drain connection according to the instructions packed with the drain.
Install the final stud wall.
Open the water supplies and check all connections for leaks.
Run water into the base and check the drain connection for leaks.
Connect the P-trap.

4. Complete the Installation

Shim the framing so the finished wall has room to overlap the base flange.
Cover the framing and walls with water-resistant wall material.
NOTE: To ensure proper fit of the shower door, install 1/2" (13 mm) to 1-1/4" (32 mm) thick wall
material (as measured from the 2x4 stud framing).