4.4)
ERRORS: these appear during operation, combined with a beep and fl ashing LED
Worklights, to notify the operator of procedural or operational errors.
Message
Error description
The pressure release button (5) was
pressed before the control parameters
ERROR
were reached (Force/Pressure).
Interruption of the signal from the NTC
temperature probe of the battery.
NTC
FAULT
Abnormal power consumption of the
motor for more than 3 seconds.
001
The tool stops.
Output voltage of the pressure transmit-
002
ter is out of the pre-set range.
Failure to reach the set pressure within
003
30 seconds of continuous operation of
the machine.
Overcharging of the battery with protec-
tion tripping.
004
The tool stops.
Error screens are displayed for about 30 seconds before being reset, but will display
repeatedly in the event of permanent anomalies.
5. CONNECTION TO COMPUTER (Smartool technology)
The memory card integrated in the tool records operating data for transfer via the USB
cable supplied.
To view and manage this data, go to www.cembre.com and register in the dedicated area,
then download the free Cembre software CEM_SWBT01.
Keeping the Firmware of the tool updated, via free of charge download from here, will
optimise the tool's performance.

6. RETURN TO Cembre FOR OVERHAUL

In the case of a breakdown contact our Area Agent who will advise you on the problem
and give you the necessary instructions on how to dispatch the tool to our nearest service
Centre; if possible, attach a copy of the Test Certifi cate supplied by Cembre together
with the tool or fi ll in and attach the form available in the "ASSISTANCE" section of the
Cembre website.
Solution
Repeat the work cycle and wait for the motor
to stop automatically.
Replace the battery.
If the problem persists, please contact
Cembre.
Wait for the display to turn off (60 sec.) or
remove and re-insert the battery, then re-
start the tool.
If the error occurs frequently, contact Cem-
bre.
Repeat the work cycle; if the error occurs
frequently, contact Cembre.
Repeat the work cycle; if the error occurs
frequently, contact Cembre.
Wait for the display to turn off (60 sec.) or
remove and re-insert the battery, then re-
start the tool.
If the error occurs frequently, contact Cem-
bre.