Return To Cembre For Overhaul - Cembre B1350L-C Manual De Uso Y Mantenimiento

Herramienta hidraulica de crimpado a bateria
Ocultar thumbs Ver también para B1350L-C:
Tabla de contenido

Publicidad

Idiomas disponibles
  • ES

Idiomas disponibles

4.4)
ERRORS: these appear during operation, combined with a beep and fl ashing LED
Worklights, to notify the operator of procedural or operational errors.
Message
Error description
The pressure release button (5) was
pressed before the control param-
ERROR
eters were reached (Force/Pressure).
Abnormal power consumption of
the motor for more than 3 seconds.
001
The tool stops.
Output voltage of the pressure trans-
002
mitter is out of the pre-set range.
Failure to reach the set pressure
003
within 30 seconds of continuous
operation of the machine.
Overcharging of the battery with
protection tripping.
004
The tool stops.
Errors are displayed for about 30 seconds before being reset, but will display re-
peatedly in the event of permanent anomalies.
5. CONNECTION TO COMPUTER
The memory card integrated in the tool records operating data for transfer via the USB
cable supplied.
To view and manage this data, go to www.cembre.com and register in the dedicated area,
then download the free Cembre software CEM_SWBT01.
Keeping the Firmware of the tool updated, via free of charge download from here, will
optimise the tool's performance

6. RETURN TO Cembre FOR OVERHAUL

In the case of a breakdown contact our Area Agent who will advise you on the problem
and give you the necessary instructions on how to dispatch the tool to our nearest service
Centre; if possible, attach a copy of the Test Certifi cate supplied by Cembre together
with the tool or fi ll in and attach the form available in the "ASSISTANCE" section of the
Cembre website.
.
Solution
Repeat the work cycle and wait for the
motor to stop automatically.
Wait for the display to turn off (60 sec.)
or remove and re-insert the battery, then
re-start the tool.
If the error occurs frequently, contact
Cembre.
Repeat the work cycle; if the error occurs
frequently, contact Cembre.
Repeat the work cycle; if the error occurs
frequently, contact Cembre.
Wait for the display to turn off (60 sec.)
or remove and re-insert the battery, then
re-start the tool.
If the error occurs frequently, contact
Cembre.
12

Publicidad

Tabla de contenido
loading

Este manual también es adecuado para:

B1350l-ceB1350l-ctB1350l-ca

Tabla de contenido