Electric scheme HR EVO 300 Smart, HR EVO 350 Smart
LEGEND
A1 Fume extraction fan
A2 Auger's mortor
A3 automatic cleaning motor
A5 Auger's motor additional tank*
A6 Igniter
A7 Heating pump A9
A8 Heating pump coupled to second pump A10
A9 Three ways motor valve*
A10 Sanitary pump coupled to heating pump A8*
A12 Boiler consent AUX*
Use and maintenance manual HR EVO Smart
SET
vista anteriore
B1 Water probe safety boiler (S1)
B2 Water probe heating (S2)
B3 Fume probe
B4 Room thermostat/Puffer heating thermostat*
B5 Water pressure tranducer
B6 Level pellet 1
B7 Level pellet 2
B8 Water probe sanitary boiler (S3)*
B9 Flowswhitch/ thermostat sanitary boiler*
B12 Fume exttractor verifier encoder
B13 Air flow meter
B14 Pressure switch
B15 Thermostat safety pellet
B16 Thermostat safety H2O
B17 Room probe
B18 Security Microswitch firedoor-ash
B19 Microswitch of automatic cleaning system
PNO100503PX00
18.04.2014
V:2.0
MICRONOVA S.R.L.
Personalizzazione per: Micronova
B2
File: stufa orizzontale Touch slim.cdr
B19
Formato file: pdf vettoriale
coralDRAW X5
B1
Dimensioni:99 x 55,5mm.
Disegnatore: Michele Rossetti
Grigio tortora
non conduttivo
Nero 10%
non conduttivo
Trasparente
Biadesivo 3M 9088
Plexiglass spessore 3mm.
Ribassamento 1mm.
A3
B 14
EN
Rev.1 08/09/2021
Pag.33
vista posteriore
*Opt.