www.renishaw.com
Pin no.
1
2
3
4
5
6
7 to 12
13
14
15 to 19
20
21
22
23
24
25
26
27
28
29
30
31
32
33
34
35
36
37
38 to 43
44
Shell
Issued 04 2019
Function
+24 Vdc
Air
X brake
Y brake
Z brake
Output 0
Reserved
Input 0
Input 1
De-clutch
Reserved
Low air
Crash
Reserved
X axis outer limit
- X axis outer limit
Y axis outer limit
-Y axis outer limit
Z axis outer limit
-Z axis outer limit
X axis inner limit
-X axis inner limit
Y axis inner limit
-Y axis inner limit
Z axis inner limit
-Z axis inner limit
24 V return (0 V)
Reserved
24 V return (0V)
Screen
Description
Supply provided for use on CMM switched
Output to control an air solenoid
Output to control the X brake
Output to control the Y brake
Output to control the Z brake
General purpose output signal
General purpose input signal
General purpose input signal
CMM de-clutch signal
Low air pressure switch input
Crash detector switch input
CMM X axis limit switch input
CMM X axis limit switch input
CMM Y axis limit switch input
CMM Y axis limit switch input
CMM Z axis limit switch input
CMM Z axis limit switch input
CMM X axis limit switch input
CMM X axis limit switch input
CMM Y axis limit switch input
CMM Y axis limit switch input
CMM Z axis limit switch input
CMM Z axis limit switch input
Common reference line for input and output
signals
Common reference line for input and output
signals