10.7 Check that the water connections do not leak.
10.8 Slide the housing over the pipe.
10.9 Insert the housing into the suspension rail.
10.10 Alight with the guide socket (b) and the tension bolts (a).
Do not fasten the tension bolts (a).
10.11 Mark the remaining drill holes.
10.12 Loosen the tension bolts and remove the guide socket.
10.13 Remove the housing.
10.14 Drill holes in accordance with these markings.
10.15 Insert the wall plugs.
10.16 Pull the protective film off from the housing.
10.17 Seal the housing with e.g. Chromol (not included, see
Important!
The solenoid valve must be connected before the power supply is connected.
10.18 Install the cable connection between the solenoid valve cartridge (c) and the control
unit (d).
10.19 Connect the control unit (d) to the battery (e).
10.20 Slide the housing over the pipe.
10.21 Insert the housing into the suspension rail.
10.22 Adjust, using the tension bolts (a) and the guide socket (b).
Do not fasten the tension bolts (a).
10.23 Fasten the housing.
10.24 Fasten the tension bolts (a).
10.25 Vertically align the hole on the tension bolt (a).
10.26 Install the fitting.

11. Function

Hygiene flush
The hygiene flush has been factory-set in such a way that water will flow for
3 minutes every 24 hours once the power supply has been connected. The solenoid
valve cartridge is opened.
11.1 Press the "Test" button on the remote control (not part of delivery scope, ssee
chapter
18, accessories).
• The control unit will switch to hygiene mode.
• The LED flashes slowly (see diagram).
11.2 Press the "ON" button on the remote control.
• Water will flow for the pre-set time.
6
chapter
18, accessories).