Descargar Imprimir esta página

Manually Terminating Calibration / Reconditioning; End-Of-Service-Life Indication; Radio Or Battery Charging Procedure - Motorola IMPRES 2 Manual Del Usuario

Ocultar thumbs Ver también para IMPRES 2:

Publicidad

Idiomas disponibles
  • ES

Idiomas disponibles

  • ESPAÑOL, página 99

Manually Terminating Calibration / Reconditioning

At any time during IMPRES or IMPRES 2 battery discharge (Steady
Amber), Calibration / Reconditioning may be terminated. Perform the
following steps:
1. Remove the battery from the charger pocket.
2. Within 5 seconds, reinsert the battery into the charger pocket.
Battery discharge immediately terminates, and Normal battery
charging starts. The LED indicates Charge Status.

End-of-Service-Life Indication

As batteries are used, normal wear reduces available capacity. At the
successful completion of Calibration / Reconditioning, IMPRES
chargers compare IMPRES battery capacity to the battery Rated
Capacity. When the capacity is at a very low value, the IMPRES battery
may be nearing its End of Service. The IMPRES battery remains
usable. In some scenarios, it may be desirable to deploy the battery to
someone who does not require large battery capacity to complete a
work shift.

Radio or Battery Charging Procedure

Batteries charge best at room temperature. Batteries may be attached
to a radio or stand-alone.
1. Place the APX IMPRES 2 Adaptive Charger on a flat surface.
2. Firmly insert the power cord into the charger AC Socket on the back
of the charger.
3. Plug the power cord into a matching power outlet.
4. Upon successful power-up, each pocket Status LED will flash
Green for 1 second and "IMPRES 2 CHARGER" will be displayed.
If the Status LED's do not flash and no message is displayed, check
power cord connections.
5. Insert the radio with battery or stand-alone battery into an available
pocket.
10

Publicidad

loading