NOTICE! Beware of damage
Observe the structural engineering of the vehicle and seal of all
openings made when installing the under-bench air conditioner.
Note on transport
Always have someone help you carry the under-bench air conditioner.
Always lift the under-bench air conditioner to move it and never drag it
over the floor (fig. 2 A).
Do not use the ventilation slots to lift it (fig. 2 B).
Note on installation location
To install the machine it is necessary to create openings in the floor.
These openings must be accessible and must not be covered by any
parts of the vehicle.
Before installing the under-bench air conditioner, check whether any vehi-
cle components could be damaged by the installation of the under-bench
air conditioner (such as lamps, cupboards, doors).
Make sure no combustible objects are stored or installed near the air out-
let. A distance of at least 50 cm should be kept.
The inclination of the installation surface may not exceed 10°.
For safety reasons, note the location of existing wiring harnesses, wires
and other components within the installation area, in particular those
which are not visible, when installing the under-bench air conditioner
(when drilling or screwing etc.).
To obtain the optimal air-conditioning in the vehicle, install the under-
bench air conditioner in a central position, in a compartment or a similar
housing.
Choose a place that is easily accessible for servicing as well as disassem-
bling and installing.
Place the assembly template into the chosen compartment and check the
space available for the openings in the floor.
To minimize the transmission of noise and vibration during operation, the
under-bench air conditioner should have a all around minimum clearance
of 30 mm to walls and furniture.
The under-bench air conditioner must be installed on the floor.
Keep a distance of 200 mm between the front of the under-bench air
conditioner and the walls of the compartment to facilitate filter replace-
ment.