Problem
Cause
Water enters the
The condensation water drainage
vehicle
openings are clogged up.
The seals are damaged.
Under-bench air
No supply voltage (230 Vw) con-
conditioner does
nected.
not switch on.
The voltage is too low (under
200 Vw).
The voltage converter is defective.
The defective thermal protection is
defective.
The electrical fuse of the power
supply is too low.
Under-bench air
The air filter is obstructed.
conditioner stops
The voltage is too low (under
working.
200 Vw).
The voltage converter is defective.
The defective thermal protection is
defective.
The condenser fan is damaged.
The heat exchange coils are polluted.
The external blower is defective.
Under-bench air
One of the temperature sensors is
conditioner does
defective.
not switch off.
EN
Troubleshooting
Remedy
➤ Clean the drainage openings
for condensation water.
➤ Contact an authorised work-
shop.
➤ Check the power supply.
➤ Contact an authorised work-
shop.
➤ Check the electrical fuse of the
power supply.
➤ Clean the air filter.
➤ Contact an authorised work-
shop.
➤ Contact an authorised work-
shop.