Descargar Imprimir esta página
Honeywell Home TL116A Instrucciones De Instalación
Honeywell Home TL116A Instrucciones De Instalación

Honeywell Home TL116A Instrucciones De Instalación

Publicidad

Idiomas disponibles

Idiomas disponibles

Enlaces rápidos

TL116A
TL116A1008, TL116A1016
READ BEFORE INSTALLING
ABOUT YOUR NEW
THERMOSTAT
This thermostat is designed to control an electric heating
system such as a baseboard heater, a convector or a fan-
forced heater.
The thermostat CANNOT be used with:
• a resistive load under 1.25 A
• a resistive load over 12.5 A (120/208/240V)
• a system driven by a contactor or a relay (inductive
load)
• a central heating system
Supplied Parts:
• One (1) thermostat
• Two (2) screws
• Two (2) solderless connectors for copper wires
CAUTION
FIRE HAZARD
Special CO/ALR solderless connectors must be
used if the thermostat will be connected to
aluminum wires.
INSTALLATION
WARNING
ELECTRICAL HAZARD
Can cause electrical shock or equipment damage.
Disconnect power before beginning installation.
The installation must be performed by a certified
electrician and must comply with electrical codes
of your region.
1. Connect the thermostat as shown.
TWO-WIRE INSTALLATION
120/208/240V
2. Remove the thermostat faceplate cover by prying it
from the top or bottom with your fingers.
3. Install the thermostat onto the electrical box using
supplied screws.
FACEPLATE COVER OFF
MOUNTING SCREW OPENINGS
FOUR-WIRE INSTALLATION
120/208/240V
M38218
SETPOINT RANGE LIMIT PINS
M38219
INSTALLATION INSTRUCTIONS
4. To limit the setpoint temperature range, insert the
pins in the orifices corresponding to the minimum
and maximum temperature limits.
WARNING
ELECTRICAL HAZARD
Use only the supplied plastic pins. Do not insert
metal objects in the holes.
5. Place the faceplate cover back.
FACEPLATE COVER ON
6. Apply power to the heating system.
TECHNICAL SPECIFICATIONS
Supply
120 VAC, 50/60Hz
208 VAC, 50/60Hz
240 VAC, 50/60Hz
Temperature setting range:
5°C to 27°C (41°F to 80°F)
Operating temperature:
0°C to 50°C (32°F to 120°F) non-condensing
Storage temperature:
-20°C to 50°C (-4°F to 120°F)
CUSTOMER ASSISTANCE
If you have any questions on your thermostat, please go to
www.resideo.com, or call Resideo Customer Care toll-free
at 1-800-468-1502.
WARNING
MERCURY NOTICE
If this product is replacing a control that contains
mercury in a sealed tube, do not place the old
control in the trash. Contact your local waste
management authority for instructions regarding
recycling and proper disposal.
Energy Verified
Only
SETPOINT RANGE LIMIT POSITIONS
M38220
TEMPERATURE SETTING KNOB
M38221
Table 1.
Minimum
Maximum
Load
Load
1.25 A (150 W)
12.5 A (1500 W)
1.25 A (260 W)
12.5 A (2600 W)
1.25 A (300 W)
12.5 A (3000 W)
69-2525EFS-07

Publicidad

loading

Resumen de contenidos para Honeywell Home TL116A

  • Página 1 TL116A TL116A1008, TL116A1016 INSTALLATION INSTRUCTIONS READ BEFORE INSTALLING 4. To limit the setpoint temperature range, insert the pins in the orifices corresponding to the minimum and maximum temperature limits. ABOUT YOUR NEW THERMOSTAT SETPOINT RANGE LIMIT POSITIONS This thermostat is designed to control an electric heating...
  • Página 2 TL116A TL116A1008, TL116A1016 NOTICE D'INSTALLATION LIRE AVANT L'INSTALLATION 4. Pour limiter la plage de réglage de la température, insérer les butées dans les orifices correspondants à la température minimale désirée et à la température maximale désirée. À PROPOS DE VOTRE...
  • Página 3 TL116A TL116A1008, TL116A1016 INSTRUCCIONES DE INSTALACIÓN LEER ANTES DE INSTALAR 4. Para limitar el rango de temperatura del punto de ajuste, inserte los pasadores en los orificios que cor- respondan a los límites mínimo y máximo de tem- peratura. ACERCA DE SU NUEVO TERMOSTATO POSICIONES LÍMITE DEL PUNTO...
  • Página 4 ©2020 Resideo Technologies, Inc. All rights reserved. The Honeywell Home trademark is used under license from Honeywell International, Inc. This product is manufactured by Resideo Technologies, Inc. and its affiliates. Tous droits réservés. La marque de commerce Honeywell Home est utilisée avec l’autorisation d’Honeywell International, Inc.

Este manual también es adecuado para:

Tl116a1008Tl116a1016