Alarm signals

In the event of a working defect, the system informs the user about the type of failure occurred.
The following table summarises the alarms, kind of problem and possible solution:
Display
ALAR 1
BLACK OUT
PROBE
ALAR 2
EXHAUST
HOT
ALAR 3
EXHAUST
FAN
ALAR 4
FAILURE
NO
ALAR 5
LIGHTIN
NO
ALAR 6
PELLET
SAFETY
ALAR 7
THERMAL
FAILURE
ALAR 8
DEPRESS
ERROR
ALAR B
TRIAC
COCLEA
PROBE
ALAR C
WATER
HOT
ALAR D
WATER
PRESS
ALAR E
WATER
SERV
Regular checks should be carried out by the user, who should only contact the Authorized
Assistance Center if no solution is found.
Kind of problem
There is no power supply
The smokes sensor is broken or not con-
nected to the pcb
Smokes temperature too high
Smokes extractor blocked or broken
The Thermostove cannot start up
This is the rst light-up
The pellet thermostove switched off while
working
The water temperature exceeds 90°C. The
circulating pump is blocked or there is no
water in the hydraulic system
Obstructed ue
The cochlea loads too much pellet
Water probe faulty
Water temperature too high
Water pressure too high
The Thermostove has worked for 1300
hours. Supplementary maintenance requi-
red
Solution
As soon as the power supply is back, the Thermostove starts a
cooling cycle. After completing the cycle it starts working au-
tomatically
Contact an Authorized Assistance Center
Switch off the Thermostove, allow it to cool down and perform
ordinary cleaning. If the problem persists, contact an Authorized
Assistance Center for cleaning the Thermostove and the ue
Contact an Authorized Assistance Center
Fill in the tank with pellets
Start up again
Fill in the tank with pellets
Check the power supply on the pump.
Check limestone does not block the pump impeller
Clean the ue or check there are no obstructed grids near the
smokes exhaust
Contact an Authorized Assistance Center
Contact an Authorized Assistance Center
Allow the thermostove to cool down. If the problem persists,
contact an Authorized Assistance Center and have the hydraulic
system checked
Allow the thermostove to cool down. If the problem persists,
contact an Authorized Assistance Center and have the hydraulic
system checked
Contact an Authorized Assistance Center
35