Hydraulic Control And Connectors - Atlas Copco HYDRAULIC PAC 30 Instrucciones Para El Operario

Tabla de contenido

Publicidad

Idiomas disponibles
  • ES

Idiomas disponibles

  • ESPAÑOL, página 23
HONDA GX390 engine
Starting
1 Turn the engine switch (A) to the position 1.
2 Turn on the fuel by setting the fuel On/Off control
(B) to the ON position
3 Move the choke control (C) to the CLOSE
position.
If the engine is warm or the air temperature
is high, the choke control should be set to
the OPEN position.
4 Set the hydraulic by-pass valve to the OFF
position.
5 Pull the starter grip (E) lightly until resistance
is felt, then pull briskly.
!
CAUTION
Do not operate the breaker when adjusting
the choke control or fuel valve. Finger injury
can be result.
6 As the engine warms up, gradually move
the choke control (C) to the OPEN position.
Stopping
1 Turn the engine switch (A) to the position 0.
2 Turn off the fuel by setting the fuel On/Off control
(B) to the OFF position.

Hydraulic control and connectors

Hydraulic Pac 30
By-pass valve (1) in off posision by starting, and in
on when using the tool.
Connectors (2) and (3) are used to connect
the powerpack to the tool as follows:
Connector (2) – Return (female).
Connector (3) – Feed (male).
English
5

Publicidad

Tabla de contenido
loading

Tabla de contenido