Connection
• The MISTRAL must be connected by qualified personnel.
• A suitable device for complete disconnection from the mains must be provided in the mains connection!
• It must be ensured that the connection lines do not come into contact with the heating element tube and are not
exposed to the hot air jet.
• The device must be connected in accordance with the connection diagram and the terminal arrangement on
page 4, 5, 6 (Wiring Diagram) of the operating instructions:
– Carry out wiring in the connection housing (9).
• ATTENTION: check dip switch settings (see wiring diagram page 4 or 5).
• Tighten the screws for connection housing (5) and cable gland for interface (6).
• Mount connection housing cover (2) with the screws (3).
• Connect MISTRAL to the electrical mains.
• Slide corresponding nozzle or refl ector onto heating element tube (4), if required.
• It must be ensured that the hot air can fl ow out freely, otherwise the device can
be damaged by the excess heat build up (risk of fi re !).
• Switch on mains.
• MISTRAL PREMIUM with Potentiometer (10) set your favored heating power.
• MISTRAL PREMIUM with Potentiometer (10) set on step 0 and cool down.
• MISTRAL SYSTEM cool down after heating (see on page 25).
• Allow device to cool down after heating mode.
Nozzles / Refl ector - change
Danger – can cause burns ! Do not touch the heating element tube and nozzle while they are hot.
Allow the tool to cool down before replacing the nozzle or refl ector.
Display description MISTRAL SYSTEM
Symbole
Heating element faulty
Device protection enabled
(overheating in the connection head)
Undervoltage
Increase Temperature
Blower active
Value fi eld for display of setpoint and actual values.
It is a four-digit segment display without decimal point
The bar graph in 5 steps symbolizes the fan speed.
At the same time, the display will appear in % (1 P - 100 P))
Blower fan speed 100 % max.
24
Symbole
Contact your Leister Service Centres
Cooling process
Voltage measurement
Reduce temperature
Indicator fi eld for visualizing units or
information for the Service menu
Blower fan speed 1 % min.
4