Product Instructions
Viega PureFlow
Crimp
®
by Compression Valves
1
2
7
8
EN
Viega PureFlow Crimp Zero Lead
by Compression Straight and
Angled Stop Valves
Viega products are designed to be
installed by licensed and trained plumbing
and mechanical professionals who are
familiar with Viega products and their installation.
Installation by non-professionals may void
Viega LLC's warranty.
Zero lead identifies Viega products meeting
the lead free requirements of NSF 61-G
through testing under NSF/ANSI 372 (0.25%
or less maximum weighted average lead content).
Turn off main water supply.
1
Slide crimp ring onto supply tube. Insert valve into
tubing and engage fully.
2
Position crimp ring ⅛" to ¼" from end of tubing.
3
Center the crimp tool jaw over the ring. Keep the
tool at 90° and close the handles completely.
CAUTION!
Do not crimp twice.
4
Check crimp connections with a GO/NO GO
gauge. A crimp is acceptable if the GO gauge fits
the ring and the NO GO does not. See current
Viega LLC
585 Interlocken Blvd.
Broomfield, CO 80021
Phone (800) 976-9819
www.viega.us
3
4
Viega PureFlow Water System Installation Manual
for additional crimping information.
5
Slide compression nut onto riser tube with threads
facing toward end of tubing that will connect to
valve.
6
Slide plastic ferrule onto PureFlow riser tube with
longer tapered portion of ferrule towards valve.
Use included brass ferrule when connecting
to copper risers only. Plastic riser ferrule
is directional and must be installed in the
correct direction to ensure a proper seal.
7
Insert tube into valve and bottom tube in socket.
8
While holding tube fully inserted in bottom of
compression fitting, slide ferrule and nut to valve
and thread nut onto valve hand tight. Tighten nut
one full turn using a suitable wrench.
ES
Prensa Viega PureFlow Zero
Lead por válvulas de corte de
compresión rectas y acodadas
Los productos de Viega están diseñados
para ser instalados por plomeros y
mecánicos profesionales, capacitados
y con licencia, que estén familiarizados con los
productos Viega y su instalación. La instalación
realizada por personal no profesional puede
anular los términos y condiciones del producto
de Viega LLC.
EN
Product Instructions
Viega Crimp by Compression Valves
This document is subject to updates. For the most current Viega
technical literature please visit www.viega.us.
ES
Instrucciones del producto
Prensa Viega por Válvulas
de compresión
Este documento está sujeto a actualizaciones. Para obtener la
documentación técnica más reciente de Viega, visite www.viega.us.
FR
Instructions produit
Viega Crimp avec vannes
de compression
Le présent document est soumis à des mises à jour. Pour consulter
les manuels techniques Viega les plus récents, veuillez visiter
www.viega.us.
PI-PF 560573 0620 Crimp x Compression Valves (EN ES FR)
5
6
6
Zero Lead identifica a los productos
Viega que cumplen los requerimientos de
la NSF 61-G mediante la realización de
ensayos de acuerdo a NSF/ANSI 372 (contenido de
plomo promedio ponderado máximo de 0.25 % o
menos).
Cortar el suministro principal de agua.
1
Deslizar el anillo de engarce en el tubo de
suministro. Insertar la válvula en la tubería y
acoplarla por completo.
2
Posicionar el anillo de engarce de ⅛" a ¼" desde
el extremo de la tubería.
3
Centrar la mordaza de la herramienta de prensado
sobre el anillo. Mantenga la herramienta a 90° y
cierre los mangos completamente.
¡PRECAUCIÓN!
No haga el engarce dos veces.
4
Comprobar las conexiones de engarce con un
medidor de PASA/NO PASA. Un engarce es
aceptable si el medidor de PASA encaja en el anillo
y el medidor de NO PASA no encaja. Para más
información sobre el engarce ver el manual actual de
instalación del sistema de agua Viega PureFlow.
5
Deslizar la tuerca de compresión en el tubo
elevador con las roscas orientadas al extremo de
la tubería que se conectará con la válvula.
6
Deslizar el casquillo de plástico sobre el tubo
elevador PureFlow con la parte cónica más larga
del casquillo hacia la válvula.