Descargar Imprimir esta página

Electrical Connection; Operation; Switching The Unit On; Stand-By - Renfert SILENT TS2 Manual Del Usuario

Ocultar thumbs Ver también para SILENT TS2:

Publicidad

Idiomas disponibles
  • ES

Idiomas disponibles

  • ESPAÑOL, página 91
Long suction hoses, tight bends and kinks will considerably reduce the extraction force at the
extraction point.
If different suction hose lengths are used, the extraction force will be lower at the extraction
point with the longer hose.
Make sure that the suction hoses are the same length and diameter. Excess hose can be cut to
size or laid in a large arch.
Avoid steep pitches or hanging points along the hose path.
4.7

Electrical Connection

EN
⇒ Electrical appliances can be connected to the coupler sockets (9, Fig. 1) at the back of the unit.
Check the connections are correct - coupler socket (A, B) - suction hose / pinch valve (A, B).
When connecting electrical appliances to the extraction unit, please ensure that the power con-
sumption of all devices connected to the unit power outlet does not exceed the total maximum
power for connected equipment (see chapter 8, "Tech. Data").
A two pole plug with protective contact is available for use as an adapter. This adapter may only
be put together by an electrician!
The protective conductor system must not be interrupted by the adapter!

5. Operation

The extractor unit is operated via the buttons on the key-pad (2, Fig. 1).
5.1

Switching the Unit On

The extractor is switched ON and OFF at the On / Off switch (3).
Once switched on (*):
• it is possible to use the suction from one or both suction tubes (see chap-
ter 5.2).
• Various settings can be programmed (see chapter 5.3).
(*)
If the self-diagnosis function is activated, this will take place after the unit is switched on,
before it is possible to work with the suction (see chapter 5.3.1).

5.1.1 Stand-By

If the unit is not used for a long period of time, the extraction unit switches to stand-by mode.
The display darkens.
Change to the stand-by mode:
• If no button has been pressed and no suction hose is open for a period of 2 min.
Leave stand-by mode:
• Press any button.
• Switch on any electrical appliance connected to the extractor.
Once switched on, the suction hose will open immediately and the extractor turbine will activate.
MENU
A
B
B
A
OFF
ON
- 10 -
3
resetdefault
OFF
ON
Fig. 6

Hide quick links:

Publicidad

loading

Este manual también es adecuado para:

2930 00502930 1050