• Only connect the device to the mains supply/ electrical
outlet if plant/outlet capacity is suitable for its maximum
power. If otherwise, immediately seek assistance from a
professionally qualified person.
• Switch off the main switch on the system when: a
malfunction is detected, you decide to perform external
cleaning maintenance, you decide not to use the device for
short or long periods.
• The device cannot be used as an activator for water
heaters, stoves, etc. nor should it discharge into the hot air
ducts of said devices.
• The device must discharge directly outside in a single
allocated duct.
• The extracted air flow must be clean (or rather free of
grease, soot, chemical and corrosive substances or
explosive and flammable mixtures).
• Never cover the device exhaust and supply to ensure
optimal
air passage.
• Maximum operating temperature: 45°C.
• The connection cables MODBUS and HMI must have a length not exceeding 60 m.
• The electrical specifications correspond to the ones on the data label A (fig.1).
The electrical system to which the product is connected must comply with current regulations.
The appliance must be installed by a professionally qualified technician.
The appliance must be wired to the power supply by way of a multi-pole isolating switch with a gap
of at least 3 mm between contacts.
Products equipped with single-phase wiring (M) engines ALWAYS require connection to 220-240V
(or only 230V where required) single-phase lines. Any kind of modification shall be considered as
product tampering and shall nullify the relative warranty.
It is not necessary to make any specific
adjustments as the appliances operate at
nominal frequencies without a preliminary
setting.

Structure and equipment

The main components of the device are:
• An external body composed of a polypropylene foam shell
and a front cover panel
• A polystyrene counter cross flow heat exchanger, whose
particular morphology guarantees a very high heat
exchange efficiency (>85%)
• Two brushless, low consumption motors with two pre-set
operating speeds
• Management electronics which oversee the power supply
and command and control of the device:
• Temperature sensors (bypass and defrosting)
• User panel, located on the front panel of the device
• Remote panel (optional)
• Two filters: G4 and M5
Meaning of the air vents (fig.2)
A: Clean air supply toward inside
B: Stale air exhaust from inside
C: Fresh air supply from outside
D: Stale air exhaust toward outside
28
1 1
2 2
A
A
B
C
D