Contents Description
P45
DHW standby time
P46
DHW user max. setpoint
P47
DHW pump Post-Circulation
P48
Max. output in DHW
P49
Not implemented
P50
Not implemented
P51
DeltaT setpoint
P52
DHW ramp
P53
No effect on adjustment
Heating deltaT adjustment tem-
P54
perature
Primary exchanger protection
P55
temperature
P56
System min. pressure value
P57
System nominal pressure value 5-20bar/10 (Only for boilers with water pressure sensor)
P58
Exchanger protection activation
P59
Heating hysteresis after ignition 6-30°C
Timer for heating hysteresis
P60
after ignition
Circulating pump deactivation
P61
with OpenTherm
Notes:
1. Parameters with more than one description vary their function and/or range in relation to the setting of the parameter
given in brackets.
2. Parameters with more than one description are reset to the default value if the parameter given in brackets is mo-
dified.
3. The Maximum Heating Power parameter can also be modified in Test Mode.
Press the Reset button to return to the Service Menu. Press the Reset button for 20 seconds to exit the card Service
Menu, or exiting occurs automatically after 15 minutes.
"Sc" - Combustion Control Parameters Menu
ONLY QUALIFIED PERSONNEL CAN ACCESS THE "Sc" MENU AND MODIFY THE RELEVANT PARAMETERS.
Press the Heating buttons to scroll the list of parameters in increasing or decreasing order. Press the DHW buttons to
view or modify the value of a parameter. To save the modified parameter press the heating"+" or "-" button (details 3
and 4 - fig. 1).
Contents Description
Sc01
Gas type selection
Sc02
Ignition gas calibration
Sc03
Ignition power
Sc04
Flue length
Sc05
Minimum power calibration
Sc06
Minimum gas valve calibration
Sc07
Flame ionization signal
240
BLUEHELIX TOP RRT K 50
Range
30-255 seconds
40-70°C
0-255 seconds
0-100%
--
--
0-20°C
1-20°C/minute
0-255 seconds
0-60°C
0-150°C
0-8bar/10 (Only for boilers with water pressure sensor)
0 = No F43
1-15 = 1-15°C/second
60-180 seconds
0 = Circulating pump active
1 = Circulating pump deactivated
Functional description
Allows the change of gas type. See "Gas conversion" on
page 235
Allows the amount of gas to be increased or decreased
in the ignition phase in case of difficult starting.
Allows the fan speed to be increased or decreased in the
ignition phase in case of difficult starting.
Allows the boiler to be arranged according to the width
and length of the flue used. To be used only with Ø50 or
Ø60 flues. See fig. 26.
Allows the minimum power to be increased, if necessary. 0 ÷ 25
Self-adaptive parameter. DO NOT MODIFY.
Displays the actual ionization current signal.
cod. 3541Q281 - Rev. 02 - 10/2020
Default
120
65°C
30
100%
--
--
0°C
5°C/minute
0
18°C
43°C
4 bar/10
7 bar/10
10°C/second
10°C
60
0
Range
Default
na / LP
na
-9 ÷ 20
0
-16 ÷ 14
0
-2 ÷ 13
0
0
Read only
EN