Ferroli BLUEHELIX TOP RRT K 50 Instrucciones De Uso, Instalación Y Mantenimiento página 221

Tabla de contenido

Publicidad

Idiomas disponibles
  • ES

Idiomas disponibles

  • ESPAÑOL, página 45
BLUEHELIX TOP RRT K 50
System water pressure adjustment
The filling pressure read on the boiler water gauge
B
(detail 2 - fig. 16) with system cold must be approx 1.0
bar. If the system pressure falls below minimum va-
lues, the boiler stops and fault F37 is displayed. Pull
out the filling knob (detail 1 - fig. 16) and turn it anti-
clockwise to return it to the initial value. Always close
2
it afterwards.
Once the system pressure is restored, the boiler will
1
activate the 300-second air venting cycle indicated on
the display by Fh.
To prevent boiler shutdown, it is advisable to periodi-
cally check the pressure on the gauge with system
A
cold. In case of a pressure below 0.8 bar, it is advisa-
ble to restore it.
fig. 16- Filling knob
System draining
The drain cock ring nut is located under the safety val-
ve inside the boiler.
To drain the system, turn the ring nut (ref. 1 - fig. 17)
counter-clockwise to open the cock. Do not use any
tools; use hands only.
To drain only the water in the boiler, first close the
shut-off valves between the system and boiler before
turning the ring nut.
1
fig. 17- Safety valve with drain faucet
221
EN
cod. 3541Q281 - Rev. 02 - 10/2020

Publicidad

Tabla de contenido

Solución de problemas

loading

Tabla de contenido