1. Operating instructions

1.1 Introduction

Dear Customer,
BLUEHELIX TOP RRT K 50 is a high-efficiency, low emissions premix condensing heat generator with heat exchan-
ger in steel and incorporated DHW production, running on natural gas or LPG and equipped with a microprocessor
control system. DHW production is ensured by a 50-liter hot water tank integrated in the unit.
The unit has a sealed chamber and is suitable for indoor or outdoor installation in a partially protected place (according
to EN 297/A6) with temperatures to -5°C (-15°C with optional frost protection kit).

1.2 Control panel

10
5
8
4
3
13
7
14a
fig. 1- Control panel
Panel legend fig. 1
1
DHW temperature setting decrease button
2
DHW temperature setting increase button
3
Heating system temperature setting decrease
button
Indication during operation
Heating
A heating demand (generated by the Room Thermos-
tat or Remote Timer Control) is indicated by activation
of the radiator.
The display (detail 12 - fig. 1) shows the actual heating
delivery temperature and, during heating standby ti-
me, the message "d2".
DHW (domestic hot water)
A DHW demand (comfort mode selected) is indicated
by activation of the faucet.
The display (detail 12 - fig. 1) shows the hot water tank
sensor temperature, and "d1" during DHW standby ti-
me.
Fault
In case of a fault (see cap. 3.4 "Troubleshooting") the display shows the fault code (detail 12 - fig. 1) and during safety
pause times the messages "d3" and "d4".
216
12
17
2
1
14b
6
9
cod. 3541Q281 - Rev. 02 - 10/2020
BLUEHELIX TOP RRT K 50
4
Heating system temperature setting increase
button
5
Display
6
"Sliding Temperature" Menu - Reset button
7
Mode selection button: "Winter", "Summer",
"Unit OFF", "ECO", "COMFORT"
8
Eco (Economy) or Comfort mode
9
DHW mode
10
Summer mode
12
Multifunction (flashing during exchanger protec-
tion function)
13
Heating
14a Burner lit (flashing during calibration function
and self-diagnosis phases)
14b Appears when a fault has occurred causing the
unit to shut down. To restore unit operation,
press the RESET button (detail 6)
17
External sensor detected (with optional external
probe)