English; Typical Applications; Technical Description - Johnson Pump SPX Heavy duty Manual De Instrucciones

Ocultar thumbs Ver también para SPX Heavy duty:
Tabla de contenido

Publicidad

Idiomas disponibles
  • ES

Idiomas disponibles

  • ESPAÑOL, página 17
> English
Circulation Pump CM90

Typical applications

Circulation in heating- and cooling system
for buses, trains and boats, etc. All-round
pump wherever selfpriming is not essential.
Features
• Centrifugal pump (must be primed)
• M agnetic drive (no shaft seal/mechanical
seal)
• Long service life.
• Wide temp. range
• Built-in thermal overload protection.
• E MC approved according to
EN55014-1:2000

Technical description

Parts in contact with liquid
Pump housing:
Impeller:
Intermediate part: PPA GF30
Bushing:
Shaft:
Impeller magnet: PA12 bonded ferrite
Magnet housing:
O-rings:
Driving unit incl motor
Drive magnet:
Screws and nuts: Stainless steel A4
Motor:
End bells:
Stator tube:
Bracket:
Clamps:
Degree of
protection:
Connections:
6
PPA GF30
PA12 GF30
Resin bonded carbon
Stainless steel,
hardened
Stainless steel
EPDM, peroxide cured
PA6 bonded ferrite
Permanent magnet
brush motor with ball
bearings
Alu, painted black
Steel, painted black
Stainless steel
Stainless steel
IP67 (EN60529)
38 mm (1½") hose
20 mm (¾") hose
Type specification
Art No
Voltage
10-24664-01 13.6 V - 12V-system
10-24664-02 27.2 V - 24V-system
10-24750-01 13.6 V - 12V-system
10-24750-02 27.2 V - 24V-system
Pressure and capacity data
(See page 25)
Spare parts
(See page 8)
Installation recommendations
The CM-series pumps are normal-priming
centrifugal pumps and should be mounted in
a manner that ensures that they are always
flooded or else be primed before being
switched on. In a closed system the pump
should be placed at a low point.
The pump should not be run dry, even if it
withstands a shorter time of dry running. Max
dry running 30 minutes. Noise may occur.
Avoid dry running because it will always
cause increased wear.
Use full hose diameter at inlet. Reduced
hose diameter at inlet gives reduced
performance and risk of cavitations witch
can cause damage in the pump.
The direction of rotation is clock-wise,
viewed from the front towards the body (see
rotation arrow).
The pump can be installed horizontally or
vertically, on a flat surface.
For vertical installation the motor should be
upwards.
To avoid air-locks when mounted horizontally,
the body should be turned in such a way that
the outlet is directed upwards or is placed
on the upper side of the pump body. (see
sketch)
Connection
38 mm/1½"
38 mm/1½"
20 mm/¾"
20 mm/¾"
Original instructions

Publicidad

Tabla de contenido
loading

Este manual también es adecuado para:

Spx magnetic drivenSpx seal-less

Tabla de contenido