● Dismantling and assembly of IP21 cover
Dismantling: 1 - Remove the M12 screws.
2 - Remove the cover(s).
3 - Screw the 4 rings or lifting rails with the M12 screws where indicated
(tightening torque = 20 N.m).
Assembly: Reverse the procedure.
T1,T1E
T4
● Specific case of transportation with height limited to 2370 mm:
assembly of cover with IP54 ventilation
Assembly: 1 - After unpacking and handling, remove the lifting rings.
2 - Reposition the cover on top of the cabinet and tighten the M12 screws
(tightening torque = 20 N.m).
3 - Open the cabinet door then remove the IP1X protections.
4 - Reconnect the electrical connections arriving at the ventilation terminal block
(identified wires, to terminals L, N, PE).
Dismantling: Reverse the procedure.