Kohler K–10970 Guia De Instalacion página 6

Tabla de contenido

Publicidad

Idiomas disponibles

Idiomas disponibles

1. Install the Control Stop (For K-10970 Only)
NOTE: The sweat solder adapter is not provided.
IMPORTANT! Flush the water supply line and then turn off the
water supply.
Install the control stop and wall flange to the water supply line as
follows:
Cut the water supply line and sweat-solder a 3/4" male NPT
threaded adapter to it.
NOTE: Install the adapter so that the centerline of the externally
threaded control stop arm matches the centerline of the spud when
assembled.
Place the wall flange over the supply line and slide it against the
finished wall.
Place the tube cover over the supply pipe. If required, cut it to
size.
NOTE: Use thread sealing compounds only on male NPT threads.
Apply thread sealant to the male NPT wall tube connection.
Thread the control stop valve onto the wall tube.
Use a strap wrench in order to tighten the control stop and align
the outlet to the urinal valve inlet.
1025497-2-A
Wall Flange
Wall Tube
Control Stop
Stop Cap
6