INSTALLATION - CLEARANCES
WARNING: Do not install or use the grill under
unprotected combustible construction without a fire
safe ventilation system.
OVERHEAD CONSTRUCTION AND
EXHAUST HOOD REQUIREMENTS
A minimum 60" [1524mm] clearance is required between
the grilling surface and the overhead construction.
When installed under combustible overhead construction,
the area above the cooking surface of the grill must be
covered with an exhaust hood. The exhaust hood provides
the protection for the combustible overhead construction.
When installed under overhead non-combustible
construction, an exhaust hood is highly recommended.

EXHAUST HOOD

When using an exhaust hood, the area above the cooking
surface of the grill must be covered with a hood larger than
the cooking area of the grill, and with a minimum of
1200CFM (cubic feet per minute) for proper outdoor
application.
6