Lp Gas Cylinder - Broil King 956084 Manual Del Usuario

Ocultar thumbs Ver también para 956084:
Tabla de contenido

Publicidad

Idiomas disponibles

Idiomas disponibles

LP GAS CYLINDER

The standard for outdoor gas appliances, ANSI Z21.58/
CAN/CGA-1.6, requires that LP gas cylinders used with LP
gas appliances be equipped with both
An Overfill Prevention Device (OPD)
A QCC®-1 Quick Closing Coupling system
OVERFILL PREVENTION DEVICE
The O P D is designed to reduce the potential of over filling
propane cylinders, thus reducing the possibility of relief valve
discharges of raw propane. The OPD causes a slower
purge/fill operation.
QCC®-1 QUICK CLOSING COUPLING
The QCC®-1 system incorporates safety features required by
the American National Standards Institute (ANSI) and the
Canadian Standards Association (CSA).
Gas will not flow until a positive connection has been
made
A thermal element will shut off the flow of gas between
240° and 300° F
When activated, a Flow Limiting Device will limit the flow
of gas to 10 cubic feet / hour
The LP gas cylinder is not included with the Gas Grill.
Be sure to use an LP gas cylinder equipped with the OPD
and the QCC® valve.
IDENTIFICATION
The QCC®-1 valve is recognized by the external threads on
the inlet port of the LP gas cylinder valve.
The OPD hand wheel has been standardized to the shape
shown.
QCC® /OPD equipped LP gas cylinders are available from
your Gas Grill Dealer.
NOTE: Any attempt to connect the regulator, by use of
adapters or any other means, to any other valve could
result in damage, fire or injury and may negate the
important safety features in the QCC®-1 system.
SPECIFICATION
1. All LP gas cylinders used with this appliance must be
constructed and marked in accordance with the
Specifications for LP gas cylinders of the U.S.
Department of Transportation (D.O.T.) or the National
Standard of Canada, CAN/CSA-B339, Cylinders, Spheres
and Tubes for Transportation of Dangerous Goods ; and
Commission, as applicable.
2. The LP gas cylinder used for this appliance must not
have a capacity exceeding 20 lb. (9 kg). Approximately
18" (46cm) high and 12" (31cm) diameter.
3. All LP gas cylinders used with this appliance should be
inspected at every filling and re qualified by a licensed
service outlet at the expiry date (10 years), in accordance
with the DOT (USA) and Canadian Transport
Commission (Canada) codes for LP Gas Cylinders.
4. All LP gas cylinders used with this appliance must be
provided with a shutoff valve terminating in a cylinder
valve outlet No. 510, specified in the Standard for
Compressed Gas Cylinder Valve Outlet and Inlet
Connection (USA) ANSI/CGA-V-1-1977 (Canada) CSA
B96.
5. The LP gas cylinder supply system must be arranged for
vapor withdrawal.
6. The LP gas cylinder must include a collar to protect the
cylinder valve.
7. The LP gas cylinder must be installed as per assembly
instructions.
8. Never fill the LP gas cylinder beyond 80% full. A fire
causing death or serious injury may occur.
9. The LP gas cylinder valve must include a safety relief
device having direct communication with the vapor space
of the cylinder.
10

Publicidad

Tabla de contenido
loading

Tabla de contenido