SYSTEM PARAMETERS

·
System address. Use this parameter to define the system number in your installation using this parameter. The
Supermaster option (available in installations with production control board, AZX6CCP) allows you to impose the
operation mode of the system to the rest of the systems connected to the AZX6CCP in a semi-forced way:
ES
EN
FR
IT
·
Temperature range. Use this parameter to select the highest temperature in heating mode (19-30 ºC, by default 30ºC)
and the lowest temperature in cooling mode (18-26 ºC, by default 18ºC). It is also possible to disable some of the
PT
modes.
·
Hysteresis Configuration. Defines the temperature differential between the room temperature and the set-point
DE
temperature required to start applying the Algorithm RadianT. This algorithm prevents overheating in underfloor air
conditioning installations. If your installation has radiators, set this value to 0ºC. (By default 2ºC)
·
Radio channel. It activates/deactivates the wireless association module of the system.
·
Reset system (only available for master thermostat Blueface). Resets the system and returns to factory settings. To
reconfigure the thermostats, please check Initial configuration).
·
Information (only for Think thermostats). It provides information about the zone, the system, the devices and the
Webserver.

ZONE PARAMETERS

·
Associated outputs. It displays and allows you to select the control outputs associated with the thermostat.
·
Thermostat settings. Use this parameter to define the thermostat as Master or Zone.
*Note: It cannot be configured as Master if there is already another Master thermostat.
·
Use mode. The thermostats can be set in Basic or Advanced mode. They are set in Advanced mode by default. These
are the parameters you can control in basic mode: On/off and set-point temperature.
If you need to reset the thermostat to Advanced mode, access the advanced configuration menu and then activate
the advanced use mode.
·
Control stages. This parameter is used to configure both cooling and heating stages in a single zone or in all the
zones.
·
Offset. Correction factor for the room temperature of the zones (range: from -2.5ºC to 2.5 ºC in steps of 0.5 ºC). It is in
0ºC by default.
·
Reset thermostat. It resets the thermostat and returns it to factory values.

INCIDENCES

If an error message is shown, you can check both the Installation Manual and the Self-diagnosis section. Please visit Myzone
web: myzone.airzone.es/productos/