34/144 Bosch Rexroth AG

5 Menus when connecting the SD301 to a SE31x/SEH312

5
Menus when connect-
ing the SD301 to a
SE31x/SEH312
The main menu bar contains the Display,
Process, System Test and System menu
items.
The corresponding menu is called up by
touching one of the menu buttons (Fig. 7).
.
Fig. 7:
The corresponding main menu button will be
displayed inversely as long as the submenu is
visible. If a submenu option has been selec-
ted, then the main menu button has a thicker
border and is thus identified as the active
menu item.
SD301 | 3 609 929 826/06.03
5.1
Display
This menu item contains the Standard, Actu-
al Values 1, Actual Values 2, Graph, and
Graph Memory menu options (Fig. 7).
The Standard, Actual Values 1, and Actual
Values 2 menu options display the following
in the top row of the display field:
– The program number P
– The step number S of the program
– The switch-off criteria and switch-off value
– The quality code QC of the program
– The result evaluation OK/NOK.
5.1.1
Standard
This menu option displays the standard
screen (Fig. 8).
Fig. 8:
The switch-off criterion and the correspond-
ing value are displayed in the upper section
(here: target function torque 34.14 Nm). The
values of all the monitoring functions and the
1)
counter readings
of the OK/NOK counter (if
an OK/NOK counter has been configured)
can be scrolled through in the lower section.
1) Displayed inversely when counting up
reaches the default value or counting
down reaches zero