INSTALLATION MANUAL
Do not use the device for positioning at work, but if required, use an addition separate system.
After having extracted and reinserted the metal cable inside any cable guides present, verify
that the cable is correctly inserted inside them.
In case of damage to the cable guides, where present, they must be replaced immediately.
Do not use damaged cable guides.
Fall clearance distance
The fall clearance distance is the minimum distance needed under the feet of the operator in
order to avoid the collision with the structure, the ground, or other obstacles, in case of a fall
from a height.
Before and during each use you must keep into account the indicated fall clearance distance
value.
Should the user be below the indicated fall clearance distance height, it might happen that he's
not protected from falls: therefore it is suggested to adopt supplementary measures during the
climbing or the descent.
The minimum distance is 2 meters.
Documentation
The installation documentation provides certification that the installation was carried out
correctly. It also serves as a basis for periodic inspections, with essential information as the
fixings may not be visible or accessible.
Inspection
Periodic inspection
The guided type fall arrester including a rigid anchor line must be inspected by a competent
person accredited by FALL SAFE®, at least once every 12 months or whenever a fall or
damage occurs.
The following parameters must be followed:
All tightening and connections should be checked and threaded blockers should be placed
whenever possible
FALL SAFE®
21