16
Oval-U 100
WARNING
This heater may be washed only on its external
areas provided:
■ The burner box is disconnected from the electri-
cal supply.
■ The burner box access panel is closed and
securely latched.
■ Water spray nozzle shall not discharge within 6
feet of the burner box and its tubes.
■ The water pressure does not exceed 45 PSIG
for 10 seconds on each side of burner box.
■ The burner box is not reconnected to electrical
supply for a minimum of 1 hour or until the it is
thoroughly dry.
Improper cleaning can cause severe personal
injury or property damage due to water and/or
cleaning solution:
■ In electrical components, connections and wires
within the burner box causing electrical shock or
component failure.
■ On gas control components causing corrosion
which can result in gas leaks and fire or explo-
sion from the leak.
Clean internal components of the burner box with a
soft, dry brush or cloth, or compressed air.
Maintenance Instructions
Before Each Use:
1. Check to make sure the heater's surrounding area
is kept clear and free from combustible materials,
gasoline, and other flammable vapors and liquids.
2. Regulators must be periodically inspected to make
sure the regulator vents are not blocked. Debris,
insects, insect nests, snow, or ice on a regulator
can block vents and cause excess pressure at the
appliance.
3. Check all hose and tubing assemblies for cracks,
cuts, abrasions or ruptures. Replace any hoses that
are suspect.
4. Check all gasketing on burner box and fan housing
discharge. Ensure all is in good condition. Replace
any gasket material if suspect
Owner's Manual • Oval-U 100
Radiant Tube Heaters
Radiant Tube Heaters
5. Check overall condition of heater for cracked
or damaged components, loose screws or
bolts,nicked or cut electrical leads, etc. Replace
any suspect components.
6. For safety as well as for optimum performance
at the heater, it is necessary to keep the outside
of the heater free of dust, dirt or any combustible
material. If any operational component shows
signs of rust or corrosion, replace the component
immediately.
7. Check all warning or instruction labels, data-
plates, etc. If any are lost or become hard to
read, replace them immediately. Do not operate
the heater until you have all instructions and can
read and understand them.
Annually:
1. Check the air inlet assembly. Ensure the air inlet
assembly and its duct are free of blockages.
2. Have your gas supplier check all gas piping for
leaks or restrictions in gas lines. Also, at this time
have your gas supplier clean out the sediment
trap at the inlet of the burner box of any debris
that may have accumulated.
3. Regulators can wear out and function improperly.
Have your gas supplier check the date codes
on all regulators installed and check delivery
pressures to the appliance to make sure that the
regulator is suitable for continued use.
General Service
Instructions
WARNING
Burn Hazard
■ Heater surfaces are hot for a period of time after
the heater has been shut down.
■ Allow the heater to cool before performing
service, maintenance, or cleaning.
■ Failure to follow this warning will result in burns
causing injury.