Descargar Imprimir esta página

LCN 4050 Serie Instrucciones De Instalación página 4

Ocultar thumbs Ver también para 4050 Serie:

Publicidad

Idiomas disponibles

Idiomas disponibles

Check closing time, and adjust closer if needed.
Opening the regulation valves (described below) too
far may result in the closer leaking oil! This may result
in closer and property damage, and personal injury.
FOLLOW ALL INSTRUCTIONS CAREFULLY.
L Valve must be closed CW to seat, never more than 3 turns
CCW from seated position. Adjust the valves in 1/4 turn
increments or less at a time. DO NOT TURN MORE THAN
3 FULL ROTATIONS. THIS WILL CAUSE THE CLOSER TO
LEAK OIL!
L DO NOT ADJUST THE LATCH SPEED IF THE DOOR DOES
NOT LATCH. If this occurs, adjust the spring force.
1. Open the door to 90°, measure how long the door takes to
close and latch. A typical closing time is 5 to 7 seconds, evenly
divided between main speed and latch speed.
2. If the closing time needs to be adjusted, use a 3/32" hex
wrench to adjust the closer valves described below.
a. Backcheck (BC)- this controls door s peed opening as the
door angle approaches 90°. Do not use as a door stop.
b. Main Speed (MD)- this controls main speed for standard
Screw Type
Wood (for wood doors & frames)
Machine (for metal doors & frames)
Requires hole drilling & tapping; best
hold.
SRT - Self Reaming & Tapping (for
metal doors & frames)
Screw Type
Screw Pack
Fifth Hole Spacer
Standard
Arm Screw
Standard
Pinion Attachment
Standard
Screw
Thru Bolt
Order TB
Screw pack
Closer Valve Adjustment
CAUTION
Optional Hold Open Arms
To adjust Optional Hold-open arm:
1. Loosen hold open nut.
2. Open door to 5° less than desired hold position
and tighten hold open nut securely.
Screw Pack
Wood &
Machine
Screw Pack
(WMS)
Standard
Standard
Picture
Z\v-20 for
attachment of the
arm (see step 6).
1 >\cx" or
1 ZM\cx" or
1 XZ\cx"
cylinders and the delay speed for delay (DA) cylinders.
c. DA Main Speed (M)- this controls the main speed for DA
cylinders. This valve is present on DA cylinders only.
d. Latch Speed (L)- this controls door speed during the last
few degrees of door closing.
e. PA Selector (P)- this needs to be turned in completely for
Parallel Arm (PA) mounting.
3. Turn the valves clockwise to decrease door speed, and
counterclockwise to increase door speed. The latch speed and
main speed should be adjusted together.
BC
M MD
L
P
Picture
Mounting
4 @ 2 M\,"
4 @ 2 Z\v"
4 @ 3"
Notes
4
L
M
MD
P
= Backcheck valve
= Main speed valve
= Latch speed valve
= PA selector valve
Cylinder
PA Shoe
5th Hole Mounting
Mounting
(PA Shoe Only)
2 @ 1 Z\x"
1 @ 2"
4 @ B\,"
1 @ 1 Z\x"
1 @ 2"
4 @ 1 Z\x"
BC
L
P
M
BC

Publicidad

loading

Productos relacionados para LCN 4050 Serie

Este manual también es adecuado para:

4050 da serie