be withdrawn from use and removed from any ex-hazardous areas immediately . Measures
must be taken to prevent any accidental restarting of the device . The safety of the device may
be compromised, if, for example:
Malfunctions occur .
The housing of the device shows damage .
The device has been subjected to excessive loads .
The device has been stored improperly .
Markings or labels on the device are illegible .
We recommend that a device displaying errors or in which an error is suspected be sent back
to i.safe MOBILE GmbH to be checked .
EX-RELEVANT SAFETY REGULATIONS
Use of this device assumes that the operator observes the conventional safety regulations and
has read and understood manual, safety instructions and certificate .
The following safety regulations must also be complied with:
Inside ex-hazardous areas the covers of all interfaces must be closed .
To ensure the IP-protection, it has to be ensured that all gaskets are present
and functional . There must be no large gap between the two halves of the housing .
The device may only be charged outside ex-hazardous areas using the i.safe PROTECTOR 2.0
or i.safe PROTECTOR 3.0 USB-cable or other equipment approved by i.safe MOBILE GmbH .
When using the IS-HS1.1 headset, the headset must be securely fastened to the ISM interface .
Physical connections to equipment other than the IS-HS1.1 headset are only allowed outside
ex-hazardous areas using the i.safe PROTECTOR 2.0 and i.safe PROTECTOR 3.0 USB-cable
or other equipment approved by i.safe MOBILE GmbH.
The device may only be charged at ambient temperatures between +5°C . . . +35°C .
The device may not be exposed to any aggressive acids or alkalis .
The device may only be used in zones 1, 2, 21, or 22 .
Only accessories approved by i.safe MOBILE GmbH may be used .
EX-RELEVANT SAFETY REGULATIONS FOR NORTH AMERICA
Conditions of Acceptability:
The battery shall only be charged outside the explosion hazardous areas only and using a
suitably certified Class 2 power supply with the following output parameters:
V = 5VDC I = 2000mA
The smartphone must be protected against excessive UV light emission and high electrostatic
processes .
The USB interface (type C) located at the bottom side is for data transmission and it is used
in non hazardous areas . It is not permitted to open the USB interface cover in hazardous
locations .
The ISM interface of the IS530.1 located at the right side can be used within hazardous areas
with approved headsets, Remote Speaker Microphones(RSM) and add-ons .
For the ISM interface connection the intrinsically safe approved accessories must comply with
entity parameters according to document 1029AD04 i .e . Headset IS-HS1.1 is approved to be
used on ISM interface . If the ISM interface is not used, it must be securely closed by the cover
provided for this purpose .