The unit is connected to the system with a single
non polarized twisted pair.
It features the following controls and indicators (fig. 1):
ON/OFF-brightness control
(thumbweel D) (
Entry panel activation/selection (
Auxiliary control 1 (
Auxiliary control 2 (always enabled)
Door-lock release control (
(
1
) The unit can only be switched on and conse-
quently connected to the entry panel if the system is
not engaged with other calls.
(
2
) Auxiliary control 1 and the door-lock release con-
trol can only be used via the monitor when the unit
is switched on.
4
WARNINGS FOR THE USER
- Do not open or tamper with the unit: high volt-
age inside.
- Be careful not to knock or bang the unit as this
might break the picture tube resulting in flying glass.
- Always use the services of skilled personnel to
remedy faults, make changes or service the
installation's units (power supplier etc.).
Function of jumper SW1 (Call attenuated)
1
Normally supplied ready inserted. Remove the jum-
per SW1 (fig. 6) in the event the volume of the call
note is to be attenuated, or if you have a number of
receivers activated by the same call.
Maximum number of receivers activated by same
call:
- 3 with normal call (jumper SW1 inserted);
- 2 with normal call and 6 with attenuated call (jumper
SW1 not inserted).
Personal door-bell
The unit is fitted with a differentiated call input for
5
calls from the occupant's door, producing a contin-
uous note lasting 2 s.
Entry panel selection in installations with a
number of entry panels
To use this function, turn on the monitor by pressing
the button entry panel connection. Next, press the
same button again to select the entry panels.
NOTE. If a call is made from the entry panel during
selection, the process is aborted.
If said call is being made to the user making the
selection, the monitor features the image from the
entry panel the call is made from.
If the call is made to a different user, the image on
the monitor disappears.
Resistive load termination
The unit features a jumper SW3 (fig. 6) for the
impedance terminating the signal line.
SW3
Remove the jumper if the line continues towards
other receivers.
SW1
Function of each terminal
12÷16V AC, 14÷18V DC
monitor supply voltage
ground
door-bell
B line
Technical features
• Video standard: CCIR (EIA).
• Picture tube: 4" (10 cm).
• Supply voltage: local 12 to 16V AC or 14 to 18V DC,
centralized 14 to 18V DC.
• Current demand: max. 450mA (2mA on stand-by).
• Maximum number of receivers that can be con-
nected to control unit XA/300LR: 100.
• Maximum number of receivers that can be con-
nected to an X2 entry panel: 64.
• Bandwidth response at –3dB: 4 MHz.
• Automatic gain control for input signal: 46 dB.
• Call signal: two-tone lasting 30 s.
• Working temperature range: 0 °C to +35 °C.
6
• Dimensions: 195x230x72 mm.
1
)
1
)
2
)
)
2
Installation instructions
WARNING. It is recommended to install the monitor
in a dry place.
Slide the locking latch as shown in figure 2. Slide
the steel frame out, and fix it on the wall at a suita-
ble height by using the screws and retainers inclu-
ded in the pack.
Please, pay attention to place the frame with the
indication TOP in upper position, and make the
hole, figure 3, to coincide with the cable junction
box.
Unscrew the two screws, figure 4, and take the left
part of the housing out.
Pass the cables through the slot at the bottom of the
housing, place the monitor on the steel frame and
fix it by sliding it downwards, figure 5.
To avoid undesired falls of the monitor caused by
accidental shocks, lock it by sliding the latch to the
right.
Proceed the opposite way to unmount the monitor.
Make all the connections and fix the cover of the
left part of the housing with the two screws.
NOTE. Connect wires to terminals in accordance to
VM/300.
WARNING. In installations with XA/300LR we
recommend you gather up the ID (SN) codes,
applied on the outside of the housing, and enter
them in the tables that come with the XA/300LR,
MPP/300LR and IPC/300LR.
INSTALLATIONS-
D
ANLEITUNG
ACHTUNG! NUR FÜR INSTALLATEUR
Diese Anleitungen sind der Innensprechstelle
beizufügen.
FLACHMONITOR MIT HÖRER VMF/300
WANDAUSFÜHRUNG
Monitor mit Mitseh- und Mithörsperre für den mit
System 300 kompatiblen Audio-, Video- und
Datenempfang geeignet.
Das Gerät ist an die Anlage über eine ungepolte
Telefonschleife allein verbunden.
Mit folgenden Steuerfunktionen und Meldungen
(Abb. 1) ausgestattet:
An/Aus - Helligkeit (Knopf D)
Einschaltung und Auswahl der Außenstation (
Zusatzsteuerung 1 (
)
2
Zusatzsteuerung 2 (stets eingeschaltet)
Türöffnertaste (
2
)
(
1
) Die Einschaltung des Geräts und der ansch-
ließende Anschluss an die Außenstation sind nur
möglich, wenn die Anlage nicht durch andere
Verbindungen besetzt ist.
(
2
) Die Zusatzsteuerungen 1 und die Türöffnerfunk-
tion sind nur bei eingeschaltetem Gerät über den
Monitor einschaltbar.
HINWEISE FÜR DEN BENUTZER
- Bitte Gerät nicht öffnen oder aufbrechen; hohe
Spannung vorhanden.
- Zur Vermeidung eines Bildröhrenbruchs mit
demzufolgenden Glasscherben Stöße und
Schläge am Gerät vermeiden.
- Sich
bei
Störungen,
Änderungen
Reparaturen an den Anlagengeräten (Netzgerät,
etc.) nur an Fachpersonal wenden.
Belegung der Überbrückungsklemme SW1
(Abschwächung des Anrufs)
Wird gewöhnlich schon eingefügt geliefert. Falls
man die Lautstärke des Ruftons herabsetzen möch-
te ist die Überbrückungsklemme SW1 (Abb. 6)
abzunehmen, oder mehrere Sprechstellen über
denselben Anruf aktiviert werden.
1
)
oder

Publicidad

loading