To measure current, do the following:
1. Set the rotary switch to 40
to switch between DC and AC measurement mode.
2. Hold the Meter tight, don't release. The Hall components are very senstive not only to the
magnet but also to heat and machines reaction force. Any shock will cause the changing in
reading in the short time.
3. Press the lever to open the transformer jaw.
4. Center the conductor within the transformer jaw, then release the Meter slowly until the
trasnformer jaw is completely closed, Make sure the conductor to be tested is placed at the
center of the transformer jaw, otherwise it will casue deviation.
The Meter can only measure one conductor at a time, to meausre more than one condutor at a
time will cause deviation.
Note:
REL
- Press
to subtracts a stored value from the present measurement value and displays a
result.
- When current measurement has been completed, disconnect the connection between the
conductor under test and the jaw, and remove the conductor away from the transformer jaw of the
Meter.
To preserve battery life, the Meter automatically turns off if you do not turn the rotary switch or
press any button for around 15 minutes.
The Meter can be activated by turning the rotary switch or pressing the button based on "THE
EFFECTIVENESS OF FUNCTIONAL BUTTONS" on page 24. Press SELECT to activate the Meter
will disable the Sleep Mode feature.
The Meter beeps 5 times in about 1 minute before entering Sleep Mode and it will have a 1 long
beep just before entering Sleep Mode.
To disable the Sleep Mode function, press and hold SELECT button while turning on the Meter.
A. General Specifications:
- Maximum Voltage between any Terminals and grounding: Refer to different range input
protection voltage.
- Display: 3 3/4 digits LCD display, Maximum display 3999
- Polarity: Automatically display.
- Overloading: Display OL or –OL
- Battery Deficiency: Display
- Measurement Speed: Updates 3 times/second.
- Measuremnet Deviation: The conductor being meaured is not placed in the center of the
jawt during AC/DC current measurement, it will cause extra 1% deviation based on the stated
accuracy.
- Drop Test: 1 meter drop test passed.
- Max. Jaw Size: 28mm diameter.
- Projected Max. Current conductor size: 26mm diameter.
A
A
. DC measuremnet mode is a default. Press SELECT
or 400

SLEEP MODE

SPECIFICATIONS