5. Replace the IR light window in the front opening with an IR light window from the kit.
6. Place the camera holder in its original position on the back of the camera assembly.
Important
Ensure that the IR light window is positioned in its compartment.
7. Tighten the black screws (T20, torque 2.5 Nm) to attach the camera holder to the camera
assembly.
Access the Product
Use the tools provided on the Installation and Management Software CD to assign an IP address,
set the password and access the video stream. This information is also available from the support
pages on www.axis.com/techsup/
Focus & Zoom
Focus and zoom should only be configured when installing or reinstalling the product.
To set focus and zoom:
1. Go to Video & Audio > Focus & Zoom.
2. On the Basic tab, set the zoom level using the slider. The buttons < and > move the zoom
position one step in either direction. The buttons << and >> move the zoom position in
multiple steps in either direction.
3. Click Perform auto focus to focus the camera automatically.
4. If more adjustments are needed, go to the Advanced tab.
Note
• Changing the zoom level moves the focus position. Focus should always be adjusted
after changing the zoom.
• Movements in front of the camera should be avoided during automatic focusing.
On the Advanced tab, focus can be adjusted manually:
1. Click Open iris to open the iris to its maximum position. This gives the smallest depth of
field and provides the best conditions for focusing.
2. Focus is set in the Focus window. Use the mouse to move and resize the focus window.
3. Click in the Focus position bar to focus on a desired location. The buttons < and > move
the focus position one step in either direction. The buttons << and >> move the focus
position in multiple steps in either direction.
4. When satisfied, click Enable iris to enable the iris.