Alarm management
If an anomaly occurs in the operation, the following procedure is activated:
1. acoustic alarm (beep);
2. one of the following system LEDs lights up:
3. if the anomaly concerns an error, the stove will switch off.
Prolonged pressing of the "cancel" key
CODE
ERROR/WARNING
E001
Defective control panel
Error of communication with
E002
the remote control
E004
Communication error
Ignition failure error
E101
Excessively hot supply water
Burn pot emptying system
E104
error
Temperature probe
E105
malfunction
Temperature probe
E106
malfunction
E108
Safety error
Pressure or thermal safety
E109
error
T e m p e r a t u r e
E110
malfunction
E111
Fume probe malfunction
Low pellet level
A001
(flashing icon)
Scheduled maintenance
A002
notification
(flashing icons)
A004
Low spare battery warning
Pressure sensor malfunction
A007
(flashing icon)
32
DESCRIPTION
Defectiveness of the control panel
Defectiveness of the control panel
Connection cable between board and control
panel interrupted or disconnected
If it appears during the configuration change,
ignore this error
Insufficient pellets
Pellet quality
Faulty ignition system
Dirty burn pot
Problems on the heating system
Circulator problems
Incorrect burn pot positioning
Defective return water probe
Defective puffer probe
Loading door or hatch open
Dirty fume evacuation system
Worn sealing gaskets
Insufficient combustion air
Problems on the heating system
Circulator problems
Problems of overheating of the pellet tank
Defective supply water probe
p r o b e
Defective air probe
Defective fume temperature probe
(Where present) Low level of pellets
Periodically, the stove requires maintenance
by a specialist technician
The battery is flat and should therefore be
replaced with a new one
Pressure sensor or faults card
004778190 - 08/04/2021
;
allows the display of the error code:
POSSIBLE CAUSES
LED