5.4 Reignition after a power failure
In the event of a power failure, the stove will automatically switch back on, verifying the safety conditions,
when the power supply returns.
5.5 "Keyboard lock" function
With this function, it is possible to lock use of the control panel to avoid accidental changes.
To enable/disable this function:
a) Use the
arrow keys to go to the set-up menu
b) Select the password "7" with the
c) Select the submenu
d) Set one of the following values with the
Off
" → Keypad lock deactivated
"
"Lo"
→ Only the on/off key remains enabled
Hi
→ Keypad lock activated
"
"
. Press the key
to confirm the set data.
5.6 Anti-freeze function
(in configuration 1 only)
A minimum temperature can be set below which the stove will switch on (outside the set time bands and
only of the timer is enabled). To modify the "antifreeze" temperature value:
a) Use the
arrow keys to go to the set-up menu
b) Select the password "7" with the
c) Select the submenu
d) The value will flash; modify it with the
e) Press the
key to confirm the set data.
6

ALARM MANAGEMENT

If an anomaly occurs in the operation, the following procedure is activated:
1)
acoustic alarm (beep);
2) one of the following system LEDs lights up:
3) if the anomaly concerns an error, the stove will switch off.
Press and hold the
"cancel" key to display the error code:
CODE
ERROR/WARNING
E001
Defective control panel
E002
Remote control communication signal error
E004
Communication error
Ignition failure error
E101
E105
Pellet probe alarm
E108
Safety switch error
E109
Pressure or electrical safety error
E106
Temperature probe malfunction
30
key and confirm with the
[10]
and confirm with the
and
key and confirm with the
[9]
and confirm with the
and
DESCRIPTION
and press the
key;
key.
keys:
and press the
key;
key;
OFF
3...20°C
keys (
;
);
;
POSSIBLE CAUSES
Defective control panel
Defective control panel
Connection cable between board and control panel
interrupted or disconnected.
If it appears during the configuration change, ignore
this error
Insufficient pellets
Pellet quality
Faulty ignition system
Dirty burn pot
Pellet probe disconnected or faulty
Sensor(s) connected to I01 (ref. Wiring diagram)
Pellet hopper overheating problems
Open connected sensor
Sensor(s) connected to I02 (ref. Wiring diagram)
Dirty fume evacuation system
Worn sealing gaskets
Insufficient combustion air
Defective air probe
Overheating problems
key;
key;
004778040 - 07/10/2020