Alarm Management - Palazzetti DISPLAY EASY Uso Y Funciones

Tabla de contenido

Publicidad

Idiomas disponibles
  • ES

Idiomas disponibles

6 ALARM MANAGEMENT

If a malfunction occurs, the following procedure is activated:
1. audible alarm (beep);
2. one of the following system LEDs come on:
3. if the problem concerns an error, the stove will switch off.
Pressing and holding the "cancel" button
ERROR/
WARNING CODE
Faulty control panel
E001
Remote control signal
E002
communication error
Communication error
E004
Failed ignition error
E101
Outlet water temperature too high
Temperature probe malfunction
E105
Temperature probe malfunction
E106
Safety error
E108*
Thermal safety
E108**
Incorrect pressure or thermal
E109*
cutout
Pressure error
E109**
Temperature probe malfunction
E110
Flue gas temperature probe
E111
malfunction
Low pellet level (icon flashing)
A001
Scheduled maintenance
A002
warning (icons flashing)
Low battery
A004
Pressure sensor malfunction
A007
(icon flashing)
Clean stove
----
Failed ignition error
----
* Only in the stoves equipped with micro safety-switches on the firebox door and on the pellet hopper lid.
** Only in the stoves without micro safety-switches on the firebox door and on the pellet hopper lid.
28
shows the error code on the display:
DESCRIPTION
Control panel fault
Control panel fault
Connection cable between board and control panel
interrupted or detached.
If this appears when changing configuration, ignore
the error
No pellets
Pellet quality
Faulty ignition system
Burn pot dirty
Problems with the heating system
Problems with the pump
Faulty return water temperature probe
Faulty buffer tank temperature probe
Door or loading hatch open
Problems with the heating system
Problems with the pump
Problems with overheating in the pellet hopper
Flue system dirty
Seals worn
Insufficient combustion air
Heating system malfunction
Circulation pump malfunction
Pellet tank overheating
Flue gas exhaust system dirty
Seal gaskets worn
Insufficient combustion air
Faulty outlet water temperature probe
Faulty air temperature probe
Faulty flue gas temperature probe
Pellets running out
The stove periodically requires maintenance to be
performed by a qualified technician
The back-up battery (mod. CR2032) on the
electronic board is low *
Pressure sensor or board fault.
Combustion chamber, burn pot or flue gas exhaust
system dirty.
Pressure measuring tubes detached or blocked.
Combustion air intake blocked.
No pellets; Faulty ignition heater; Worn gaskets;
Incorrect burn pot position
;
POSSIBLE CAUSES
LED
004778911 - 26/01/2022