Configuring Dip Switches - Fermax AC PLUS Manual De Instrucciones

Tabla de contenido

Publicidad

Idiomas disponibles
  • ES

Idiomas disponibles

AC PLUS Central Unit
AC PLUS Central Unit
AC PLUS Central Unit
AC PLUS Central Unit
AC PLUS Central Unit
AC PLUS Central Unit
AC PLUS Central Unit
AC PLUS Central Unit
AC PLUS Central Unit
AC PLUS Central Unit

Configuring Dip switches

6 SW1
ON DIP
1 2 3 4
DECODERS
RD
TD
CONFIG
RST
12Vdc
X
Y
TEST D.
UNIDAD CENTRAL CAC
MADE IN SPAIN
CAC CENTRAL UNIT
REF. 4410
FUSIBLE
0.5A
FUSE
POWER
TEST P.
FXL
PC
P0
PANEL 0
RX
TX
SWITCHERS
OFF
ON
RP
TP
SW3
7 SW2
ON
1 2 3 4
ON DIP
1 2 3 4
DECODERS
RD
TD
CONFIG
RST
12Vdc
X
Y
TEST D.
UNIDAD CENTRAL MDS
MADE IN SPAIN
MDS CENTRAL UNIT
REF. 2405
FUSIBLE
0.5A
FUSE
POWER
TEST P.
FXL
PC
P0
PANEL 0
RX
TX
SWITCHERS
RP
TP
OFF
ON
SW3
Configuration of central
unit number:
Makes it possible to
identify each central unit in
an installation. The central
unit number cannot be
repeated in other central
units
in
the
installation.
Page 8
DIP
FUNCTION
1
Not in use
ON DIP
1 2 3 4
2
Mode
Maintenance
ON
1 2 3 4 5 6 7 8
#CENTRAL
Speed of central
3
units network
FXL
Update central
4
unit
DIP
1..6
Configuring the central unit number (see codification figure 1)
7
Parity in connection between
central units (FXL Network)
5
6
7
8
8
Not in use
ON
ON
1 2 3 4 5 6 7 8
1 2 3 4 5 6 7 8
#CENTRAL
FXL
ON
ON
1 2 3 4
5
6
0
ON
1 2 3 4
5
6
8
ON
1 2 3 4
5
6
16
same
ON
1 2 3 4
5
6
24
ON
1 2 3 4
5
6
32
ON
1 2 3 4
5
6
40
ON
1 2 3 4
5
6
48
ON
1 2 3 4
5
6
56
Maintenance activated: Permits
programming of the decoders
connected to the central unit
through the decoders busbar.
In maintenance mode, the central
unit does not respond to the
different events of the installation.
38400 bauds
Updating central unit firmware mode
activated: Makes it possible to
update the firmware of the central
unit (LEDs X and Y go on
alternatively)
Factory Configuration:
FUNCTION
Factory Configuration:
ON
ON
ON
1 2 3 4
5
6
7
8
1 2 3 4
5
6
7
8
1 2 3 4
7
8
1
2
ON
ON
ON
7
8
1 2 3 4
5
6
7
8
1 2 3 4
5
6
7
8
1 2 3 4
9
10
ON
ON
ON
7
8
1 2 3 4
5
6
7
8
1 2 3 4
5
6
7
8
1 2 3 4
17
18
ON
ON
ON
7
8
1 2 3 4
5
6
7
8
1 2 3 4
5
6
7
8
1 2 3 4
26
25
ON
ON
ON
7
8
1 2 3 4
5
6
7
8
1 2 3 4
5
6
7
8
1 2 3 4
33
34
ON
ON
ON
7
8
1 2 3 4
5
6
7
8
1 2 3 4
5
6
7
8
1 2 3 4
41
42
ON
ON
ON
7
8
1 2 3 4
5
6
7
8
1 2 3 4
5
6
7
8
1 2 3 4
49
50
ON
ON
ON
7
8
1 2 3 4
5
6
7
8
1 2 3 4
5
6
7
8
1 2 3 4
57
58
ON
M a i n t e n a n c e
deactivated: Central
unit
functioning mode.
Updating central unit
firmware
activated: Central unit
in normal functioning
mode.
ON DIP
1 2 3 4
ON
with parity
ON
1 2 3 4
ON
ON
5
6
7
8
1 2 3 4
5
6
7
8
1 2 3 4
5
6
7
8
3
4
5
ON
ON
5
6
7
8
1 2 3 4
5
6
7
8
1 2 3 4
5
6
7
8
12
13
11
ON
ON
5
6
7
8
1 2 3 4
5
6
7
8
1 2 3 4
5
6
7
8
20
21
19
ON
ON
5
6
7
8
1 2 3 4
5
6
7
8
1 2 3 4
5
6
7
8
27
28
29
ON
ON
5
6
7
8
1 2 3 4
5
6
7
8
1 2 3 4
5
6
7
8
35
36
37
ON
ON
5
6
7
8
1 2 3 4
5
6
7
8
1 2 3 4
5
6
7
8
44
43
45
ON
ON
5
6
7
8
1 2 3 4
5
6
7
8
1 2 3 4
5
6
7
8
51
52
53
ON
ON
5
6
7
8
1 2 3 4
5
6
7
8
1 2 3 4
5
6
7
8
59
60
61
OFF
in
normal
9600 bauds
mode
OFF
without parity
5
6
7
8
ON
ON
1 2 3 4
5
6
7
8
1 2 3 4
5
6
7
8
6
7
ON
ON
1 2 3 4
5
6
7
8
1 2 3 4
5
6
7
8
14
15
ON
ON
1 2 3 4
5
6
7
8
1 2 3 4
5
6
7
8
23
22
ON
ON
1 2 3 4
5
6
7
8
1 2 3 4
5
6
7
8
30
31
ON
ON
1 2 3 4
5
6
7
8
1 2 3 4
5
6
7
8
39
38
ON
ON
1 2 3 4
5
6
7
8
1 2 3 4
5
6
7
8
46
47
ON
ON
1 2 3 4
5
6
7
8
1 2 3 4
5
6
7
8
54
55
ON
ON
1 2 3 4
5
6
7
8
1 2 3 4
5
6
7
8
62
63

Publicidad

Tabla de contenido
loading

Este manual también es adecuado para:

4410

Tabla de contenido