Message displayed
{"01 TRACTION#BLOCKAGE"}
{"02 MAX
TRACTION#TEMPERATURE"}
{"03 BATTERY SPENT"}
{"04 MAX
ELECTR#TEMPERATURE"}
{"05 BATTERY LEVEL#TOO HIGH"}
{"06 ACCELERATOR#PEDAL
FAULT"}
{"07 ERROR#TEMPERATURE"}
{"08 BATTERY LEVEL#VERY LOW"}
{"09 BATTERY LEVEL#LOW"}
{"10 TANK FULL"}
{"11 START#BLOCKAGE"}
{"12 RECOVERY TANK#EMPTY"}
{"19 SQUEEGEE#LOWERED"}
{"20 COMUNICATION#ERROR"}
The battery connector is disconnected or poorly
attached to the main wiring connector.
Firmly connect the two connectors.
The emergency/work stoppage button is pressed.
Disengage the emergency/work stoppage button.
The machine is charging.
Complete the charging operation.
The batteries are discharged.
Charge the batteries.
No operator in the driver's seat.
Solution
Stops traction motor to protect from excessive current peak. To
restore, restart the machine.
Stops traction to protect the motor from excessive continuous
current. To restore, restart the machine after the motor has coo-
led down.
Stops brush, suction and traction motor due to battery voltage
insufficient. To restore, restart the machine after the battery
charging.
Stops traction motor due to excessive temperature of the elec-
tronic control board unit. To restore, restart the machine after
the control board has cooled down.
Stops brush, suction and traction motor due to excessive bat-
tery voltage. To restore, restart the machine after having che-
cked the battery.
Stops traction for incorrect communication with the potentio-
meter (suspect detachment). To restore, restart the machine
after having checked the correct connection of the potentio-
meter.
The traction speed is reduced according to the setted value of
the parameter RID_TEMP. To restore proceed at reduced speed
until the cooling of the electronic control board unit.
Stops brush and suction motor due to battery voltage insuffi-
cient. To restore, restart the machine after the battery charging.
Stops brush motor due to battery voltage insufficient. To re-
store, restart the machine after the battery charging.
Stops suction motor because the recovery water tank is full. To
restore, empty the recovery tank.
Stops traction as the accelerator pedal is pressed down when
turning on the machine or after braking, avoiding unwanted
movements of the machine. To restore, fully release the accele-
rator pedal.
Indicates that the solution water tank is empty. To restore, it is
necessary to fill the solution water tank.
In reverse gear indicates that the squeegee has remained lo-
wered (Essential model). To restore, lift manually the squeegee
with the control lever.
Interrupted communication between the control panel keybo-
ard and the control board. Turn off the machine and verify the
integrity of the connections and try again.
Sit in the driver's seat.
The main fuse is burned.
Replace it.
The control card has overheated.
Check the operating situations that may have
caused the malfunction (high slope, etc.). Wait 30
minutes and try to avoid the same incorrect opera-
tions. If the problem persists, contact the authorised
service centre.
42