may have fallen into the suction grill, lifting the fan plate if necessary.
- If anomalous ice has formed, contact a Qualified Refrigeration Technician for assistance.
Complete the cleaning operation by reattaching the dry removable elements and by restoring the
electrical supply. Once internal operating temperature has been reached, the unit can be loaded with
the products to be displayed.
ATTENTION!: If using a water jet cleaner to clean the interior, use a LOW
PRESSURE system. Take special care NOT direct the jet onto painted or plasticised
surfaces and keep a minimum distance of 30 cm from the surface to be cleaned.
N.B.Avoid wetting fans, lights, electric cables, and all electrical devices in general during
cleaning operations.
Cleaning the condenser
The condenser must be cleaned every 30 days to remove accumulated dust:
- remove the condenser cover plate
- clean using a hard bristle brush (non metallic) or a vacuum cleaner. Take care not to fold or ruin the
condenser gills.
Clean the water collection tank
The collection tank can be removed for cleaning:
- Remove the carter, withdraw the tank and clean.
At the end of cleaning reassemble the dried parts and restore the voltage supply. Once the internal fun-
ctioning temperature is reached it is possible to load the cabinet with the products to be displayed.
N.B.Prevent the fans, lights, electric cables and all electric appliances from becoming wet
during the cleaning operations.
16.Disposal of the unit
The unit must be disposed of in accordance with your country's waste management legislation and in
respect of our environment.
This product is considered by current legislation as hazardous waste. It must therefore be collected
separately and cannot be treated as household waste nor sent to a landfill. Before disposing of the unit,
the coolant must be collected and the lubricant oil removed. The user is responsible for delivering the
product for disposal to the collection centre specified by the local authorities or manufacturer for the
recovery and recycling of materials. This product consists of 75% recyclable materials.
Materials used in construction:
- Pipes, sections and iron plates: bottom frame, uprights and shelves
- Copper, Aluminium:
- Zinc plated iron sheet:
- Polyurethane foam (R134a):
- Tempered glass:
- Wood:
- ABS
- Polysterene
- Polycarbonate
- Methacrylate
This product contains HFC, high value refrigerant with green house gas (GWP)
ARNEG uses the following types of refrigerant in cabinets manufactured with built in refrigerator unit:
R 134a; GWP
= 1300 R 404A; GWP
(100)
belonging to the HFC family, high value fluorinated gas with green house gas (GWP) disciplined by
Kyoto protocol. (Check the data plate or the adhesive plate present on the compressor to see which of
these two gases is present on the appliance)
This appliance is hermetically sealed and the refrigerant load is less than 3 kg.
It is therefore not subject to plant booklet obligation or to periodic checks for refrigerant leaks
(D.P.R.n. 147 dated 15 February 2006 Art. 3 and 4).
17.Prohibitions and prescriptions
It is recommended that the Installation and Use Manual be read carefully, so that the operator, in the
case of malfunction, is able to provide precise information to Technical Assistanceby telephone.
Before carrying out any maintenance work on the refrigerator unit, please ensure that the electrical
supply is disconnected.
05060085 01 13/07/2010
refrigerant circuit, electric plant and top light
motor base, bottom panels, coated panels, basestructure
thermal insulation
top shelves (crystal sides)
lateral frames foam insulated tank
Bumpers and handrail
Thermoformed ends
lamp protection
boards
= 3750
(100)
Denver
English
25