In the window "Device list" (fig. 6) the devices can be displayed in
three ways.
Using the arrow key at the bottom right of the screen, the follow-
ing items can be selected (fig. 7):
❑ "All": this mode displays all devices connected to Oview;
❑ "Single series": this mode displays the devices connected
to Oview in a specific series.
❑ "Control units": this mode displays only the control units con-
nected to Oview;
❑ "Devices in boot phase": i.e. any devices undergoing
firmware updates.
After selecting the required mode, the arrow keys at the top right
and left of the screen can be used to move from one series to an-
other.
03. At this point, click on the icon of the device required for access to
a second window (fig. 8) containing the areas "Control panel",
"Functions menu" and the browser bar at the bottom, with the
functions "Back", "File" and "System", the latter only enabled if
the systems are used.
The "Control panel" usually displays the following subjects (fig. 9,
10 and 10a for OX4T receiver only):
7
– fig. 9 Device description: Name – Address - Status – Last
event;
– fig. 10 Keys to control the device displayed: "Open" - "Stop"
- "Close" - "Partial open" and "Other commands"; the latter,
if selected, displays another list of commands;
– fig. 10a (for OX4T receiver only) Keys for activation (or
deactivation) of the 4 channels on the device displayed: "Out-
put 1", possibility of programming Timer 1 - "Output 2" - "Out-
put 3", possibility of programming Timer 2 - "Output 4" and
"Other commands", click on this item to enable programming
of the device in 2 control modes, i.e. "tubular motor" or
"Venetian blind".
8
9
English – 11