GENERAL WARNINGS.
All Immergas products are protected with suitable transport packaging.
The material must be stored in a dry place protected from the weather.
This instruction manual provides technical information for installing the Immergas kit.
As for the other issues related to kit installation (e.g. safety at the workplace, environ-
mental protection, accident prevention), it is necessary to comply with the provisions
specified in the regulations in force and with the principles of good practice.
Improper installation or assembly of the Immergas appliance and/or components, acces-
sories, kits and devices can cause unexpected problems for people, animals and objects.
Read the instructions provided with the product carefully to ensure proper installation.
Installation and maintenance must be performed in compliance with the regulations in
force, according to the manufacturer's instructions and by professionally qualified staff,
meaning staff with specific technical skills in the plant sector, as envisioned by the law.
IE
DESCRIPTION.
The kit contains what is required to carry out the connection of the Victrix Tera
Vip boiler.
INSTALLATION.
Assemble the connection unit as shown in the figure, taking care to interpose the
gaskets.
The filter and the connections on the system return are supplied as standard with
the product.
N.B.:
once the installation is completed, check the tightness of the gas circuit and
of the hydraulic circuit.
G
AC
Key:
G - Gas supply 3/4"
AC - Domestic hot water outlet 1/2"
AF - Domestic cold water inlet 1/2"
R - System return 3/4"
M - System flow 3/4"
VICTRIX TERA VIP
CONNECTION KIT
COD. 3.029913
AF
R
M

Publicidad

loading

Este manual también es adecuado para:

3.029913