transmitter and the control pushbutton will
be deactivated if an obstacle is detected by
one of the safety devices (for example, the
photocells);
- Hammer movement: This feature makes it
easy for the lock to release (the door wings
momentarily press against the closure stops
when the open command is given, which
facilitates release of the electric lock);
- Cycle lamp
Cycle lamp. The lamp which lights the
manoeuvring zone: it remains lit from the
moment the garage-type door begins to
open until it is completely closed (including
the time required for the automatic closure).
In case automatic closure is not enabled,
the lamp remains lit only during movement
(10-E3). Select it using the jumpers (see p.
19);
- "Operator present" function:
"Operator present" function: Gate operates
only when the pushbutton is held down (the
radio remote control system is deactivated);
- Flashing light
Flashing light activated before opening and
Flashing light activated before opening and
Flashing light
closing cycle begins;
- Type of command
Type of command:
- «open-stop-close-stop» for pushbutton
and radio transmitter;
- «open-close-reverse» for pushbutton and
radio transmitter;
- «open only» for radio transmitter.
Adjustments
- REG/FINE trimmer = Fine adjustment
of amperometric sensitivity during motor
operation
- Trimmer SENS/VEL = Adjustment of
amperometric sensitivity during operating:
min/max;
- Trimmer SENS/RALL = Adjustment of
amperometric sensitivity during slowdown:
min/max;
- Trimmer TCA = Adjustment of automatic
closing time: 2" to 120";
- Trimmer TL = Adjustment of operating
time: 13" to 120";
- Faston connectors on the circuit card
are used to select normal operating and
slowdown speeds;
Note: the opening and closing delay times
are set at zero.
Caution! Shut off the mains power
and disconnect the batteries before
and disconnect the batteries before
servicing the inside of the unit.
servicing the inside of the unit.
-5-