Description of control panel
Control panel for 24V d.c. gear motors,
powered by 230V a.c. at 50-60 Hz (single-
phase).
Designed to control EMEGA gear motors.
Designed and built entirely by CAME CAN-
CELLI AUTOMATICI S.p.A. to meet safety
standards at an IP 54 level of protection.
Housing in ABS is equipped with vents to
provide internal air circulation. Guaranteed
24 months, unless tampered with.
This control panel is powered by 230V a.c.
across terminals L1 and L2, and is protected
by a 3.15A fuse on the main power line.
Control systems are powered by low voltage
and protected by a 630mA fuse.
The total power consumption of 24V acces-
sories (which are protected by a 3.15A fuse)
must not exceed 40 W.
Safety
Photocells can be connected to obtain:
- Re-opening
Re-opening during the closing cycle (2-
C1);
- Partial stop,
Partial stop, shutdown of moving garage-
type door's, with activation of an automatic
closing cycle (2-C3);
- Total stop
Total stop
T
otal stop
(1-2), stop of the garage-type
door with the exclusion of the automatic
closing cycle. To resume the movement, use
the pushbutton or the radio control;
- Safety test function.
Safety test function. The control unit will
now check the safety system every time an
opening or closing command is given (see
p. 23).
The electric panel includes an amperome-
tric sensor for the motors which is triggered
when an obstacle blocks movement during
-4-

GENERAL CHARACTERISTICS

opening or closing. This inverts the move-
ment direction when the motor is in gear,
whereas the motor blocks if it is slowing
down. The sensitivity of the device is adju-
stable by using the trimmers 6-7-8 (page
12).
The transformers are equipped with a
guard, which in case of thermal overload will
keep the door open.
They are closed again only after the temper-
ature falls below the emergency threshold.
Accessories which can be connected to
this unit
- "Door open" signal light;
- Flashing signal light when gate is in mo-
tion;
- Cycle lamp;
- Electric lock;
- LB18 circuit card for emergency battery,
which is automatically connected in case of
power failure; battery is recharged when line
power is restored
- Radiofrequency AF board (see table
pag.25).
Other functions available
- Automatic closing.
Automatic closing. The automatic closing
timer is automatically activated at the end
of the opening cycle. The preset, adjusta-
ble automatic closing time is automatically
interrupted by the activation of any safety
system, and is deactivated after a STOP
command or in case of power failure;
- Obstacle detection: When the motor is
amperome-
stopped (door is closed, open or half-open
after an emergency stop command), the
ENGLISH