4. Installation
4.1 Safety instructions
for installation
4.2 Installation
description
4.3 Function check
WARNING
Risk of fatality due to lack of emergency opening facility!
If the product is installed without an emergency opening facility,
it may not be possible to open the door from the outside
in the event of fault. If emergencies occur inside the room during the fault,
rescue work will be hindered.
> The operator must ensure that doors to which this product is fitted
have an emergency opening facility in the event of faults.
> Häfele is not liable for damage that is attributable to failure to install
an emergency opening facility.
WARNING
Risk of fatality due to failures or faults in electromagnetically
sensitive devices!
The electromagnetic radiation of the product can cause faults in sensitive
parts (e.g. in medical equipment).
This will have an adverse effect on the functionality thereof.
> Do not place product in the vicinity of electromagnetically sensitive
devices.
> Pay attention to the safety instructions of the electromagnetically
sensitive devices.
> If you have any doubts regarding compatibility, please contact the
manufacturer.
NOTE
Damage to product due to incorrect installation!
> Adhere to the installation requirements.
> Always drill holes in the door leaf from both sides to prevent pieces
of the door from breaking away.
The installation procedure is exclusively described in pictures.
For step by step installation instructions, see picture section
starting on page 19.
When installation is complete, perform a manual function check.
Push the lever handle on the inside of the door:
Correct result:
• Latch bolt is retracted (panic function).
• The door can always be opened.
Push the lever handle on the outside of the door:
Correct result:
• The coupling is disconnected. The lever handle is in idle mode.
The door cannot be opened.
• After operating the lever handle, the return spring automatically pulls the lever handle
back into the horizontal non-operating position.
• The door cannot be opened.
If this is not the case, check the individual installation steps.